Dell XC Core XC760 Installation And Service Manual page 85

Table of Contents

Advertisement

Figure 61. Configuration 29: 24 x 2.5-inch SAS/SATA + 2 x 2.5-inch with fPERC (HBA355i)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 40. 24 x 2.5-inch SAS/SATA + 2 x 2.5-inch with fPERC (HBA355i) 
Order
1
2
3
4
5
6
7
From
SIG_PWR_1 (system board power connector)
SL3_CPU1_PA2 (signal connector on system
board)
CTRL_SRC_SB1 (fPERC controller connector)
CTRL_SRC_SA1 (fPERC controller connector)
NOTE:
Tightening the connector screws
secures the connector end.
SIG_PWR_2 (system board power connector)
SIG_PWR_0 (system board power connector)
SL11_CPU1_PB7 (signal connector on system
board)
To
BP_PWR_1 (backplane power connector)
CTRL_DST_PA1 (fPERC input connector)
BP_DST_SB1 (backplane expander signal
connector)
BP_DST_SA1 (backplane expander signal
connector)
BP_PWR_2 (backplane power connector)
BP_PWR_1 (rear backplane power connector)
BP_DST_SA1 (rear backplane signal connector)
and BP_DST_SB1 (rear backplane signal
connector)
Installing and removing system components
85

Advertisement

Table of Contents
loading

Table of Contents