3.9 Type of connection to the mains

400V 3PH + N ~
Connect the 3 phase conductors (L1, L2, L3) of the cable respectively to the terminals of the terminal board
marked with "1"(brown conductor), "2"(black conductor) and "3"(grey conductor) and the neutral (N)
conductor to the terminals marked with "4" or "5" (blue conductor); the earth conductor (yellow/green)
must be connected to the terminal marked with the symbol
board).
230V 3PH ~
Connect the 3 phase conductors (L1, L2, L3) of the cable respectively to the terminals of the terminal board
marked with "1" and "2" (brown conductor), with "3" and "4" (black conductor) and with "5" (grey
conductor); the earth conductor (yellow/green) must be connected to the terminal marked with the
symbol
(see diagram available by the terminal board).
230V ~
Connect the conductor of phase (L) of the cable to the terminals of the terminal board marked with "1",
"2" and "3" (brown conductor) and the neutral (N) conductor to the terminals marked with "4" and "5"
(blue conductor); the earth conductor (yellow/green) must be connected to the terminal marked with the
symbol
(see diagram available by the terminal board).
Mod. MKF 416 BM – MKF 464 BM – MKF 511 BM
Mod. MKF 616 BM – MKF 664 BM – MKF 711 BM
Mod. MKF 621 BM
Mod. MKF 611 C BM