Starter Relay Inspection - KYMCO YUP 250 Manual

Table of Contents

Advertisement

18
. STARTING SYSTEM

STARTER RELAY INSPECTION

Disconnect the starter relay wire connector.
Check for continuity between the yellow/red
wire terminal and ground.
There should be continuity when the starter
button is depressed.
If there is no continuity, check the starter
button for continuity and inspect the wire.
OPERATION TEST
Connect the electric tester to the starter relay
larger terminals that connect to the battery
positive cable and the starter motor cable.
Connect a fully charged battery across the
starter relay yellow/red and green/yellow wire
terminals.
Check for continuity between the starter
relay large terminals. The relay is normal if
there is continuity.
18-7
www.PlanDeGraissage.org
Starter Relay Wire
Starter Relay
YUP 250
Starter Relay

Advertisement

Table of Contents
loading

Table of Contents