Digital Inputs - Datalogic STS320 Series Installation Manual

Table of Contents

Advertisement

DIGITAL INPUTS

There are two optocoupled polarity insensitive inputs available on the reader: Input 1
(External Trigger) and Input 2, a generic input:
These inputs can be used to control (start/stop) the reading phase:
Source
Single Presence
Sensor
Two Presence
Sensors
PLC Digital Output
NOTE
The electrical features of both inputs are:
The active state of these inputs is selected in software.
An anti-disturbance filter is implemented in software on both inputs so that the mini-
mum pulse duration is ≅ 0.5 milliseconds. This value can be increased through software.
These inputs are optocoupled and can be driven by PNP type commands.
NOTE
Parameter
Reading Phase ON Input
External Trigger Leading Edge
External Trigger Leading Edge
External Trigger Leading Edge
or
Input 2 Leading Edge
Alternatively, host communication output commands (Serial or Fieldbus)
can be used to control the reading phase. See the DL.CODE Configuration
Parameters Help On Line for details.
V
= 30 Vdc max.
AB
I
= 10 mA (reader) + 12 mA (CBX) max.
IN
Polarity insensitive inputs assure full functionality even if pins A and B
are exchanged.
DIGITAL INPUTS
Reading Phase OFF Input
External Trigger Trailing Edge
Input 2 Leading Edge
External Trigger Trailing Edge
or
Input 2 Trailing Edge
INSTALLATION GUIDE 11