Inputs - Datalogic DS1500 Reference Manual

Datalogic compact laser scanner reference manual
Table of Contents

Advertisement

2
Code Verifier
If the DS1500 is used as a Code Verifier, it is possible to indicate to the scanner what
code to store as the verifier code through the WinHost program, (refer to the WinHost
Help On Line).
2.3.4

Inputs

The input available on the connector supplied with the scanner is the pin relative to
the External Trigger, as indicated below:
The External Trigger input is used in the On-Line operating Mode and tells the
scanner to scan for a code. The active state of this input is selected in software.
Refer to the WinHost Help On Line.
The yellow LED (Figure A, 5) is on when the External Trigger forces a current flow
through the EXT TRIG- and GND pins.
This input is designed to be driven by an NPN type command. The connections are
indicated in the following diagrams.
DS1500
+ 5 V
47 K
Figure 12 - External Trigger Input Command using Scanner Power
DS1500
+ 5 V
47 K
Figure 13 - External Trigger Input Command using External Power
18
Pin
Name
9
EXT TRIG-
5
GND
VS
1
EXT TRIG -
9
GND
5
VS
1
EXT TRIG -
9
GND
5
Function
external trigger -
EXTERNAL TRIGGER
V
Ground
40 Vdc max
EXTERNAL TRIGGER
V
Ground
Signal
Signal
DS1500