8.

SPECIFICATIONS

8.1 Ratings

(1) Three-phase 200V power supply
Type FR-S520E- K (-C)
Applied motor capacity (kW) (*1)
Rated capacity (kVA) (*2)
Rated current (A)
Overload current rating (*3)
Voltage (*4)
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply system capacity
(kVA) (*5)
Protective structure (JEM1030)
Cooling system
Approximate weight (kg)
*1. The applied motor capacity indicated is the maximum capacity applicable for use of the
Mitsubishi 4-pole standard motor.
*2. The rated output capacity indicated assumes that the output voltage is 230V.
*3. The % value of the overload capacity indicates the ratio of the overload current to the
inverter's rated output current. For repeated duty, allow time for the inverter and motor to
return to or below the temperatures under 100% load.
*4. The maximum output voltage does not exceed the power supply voltage. You can set the
maximum output voltage to any value below the power supply voltage. However, the
pulse voltage value of the inverter output side voltage remains unchanged at about
that of the power supply.
*5. The power supply capacity changes with the values of the power supply side inverter
impedances (including those of the input reactor and cables).
0.1
0.2
0.4
0.1
0.2
0.4
0.3
0.5
1.0
0.8
1.4
2.5
150% 60s, 200% 0.5s (inverse time characteristics)
Three-phase 200 to 240V 50Hz/60Hz
Three-phase 200 to 240V 50Hz/60Hz
170 to 264V 50Hz/60Hz
0.4
0.7
1.2
Enclosed type (IP20), IP40 for totally enclosed structure series
Self-cooling
0.5
0.5
0.8
67
0.75
1.5
2.2
0.75
1.5
2.2
1.6
2.8
4.0
4.1
7.0
Within ± 5%
2.1
4.0
5.5
Forced air cooling
0.9
1.5
1.5
Ratings
3.7
3.7
6.6
10
16.5
9
2.1
2
8