Advanced Configuration Using the Integrated SSH Shell
In most cases, configuring the CABCONS1716I to the same settings as
the R-Port devices you are connecting should allow the devices to work
with a minimum amount of configuration. However, you can also change
the default settings on each R-Port device to fit your preferences and the
needs of your application.
If you click the Connect... button next to the device you want to con-
figure, two new windows will appear. The smaller of the two is a login
screen; the other is an SSH terminal window. Click the login window and
sign in as admin (using the same password as the Web interface) to
activate the terminal window. You will see a welcome banner similar to the
following:
Baud rate: 115200 bps, 8N1
Connected to #1: (none)... (Press Ctrl-Shift-_ for menu).
You are now connected to the R-Port module in a live terminal session.
Commands you type will be echoed on the terminal screen. The module
also offers a simple menu system that allows you to change configuration
settings (similar to the function of the menus in a terminal software pack-
age). Press [Ctrl] - [Shift] – [_] (underscore) on the keyboard to access
the menu. It will be similar to the following:
RS-232 Menu (#1: (none), 115200 bps, 8N1)
Q – Disconnect
# - Send break
H – Hangup line (drop DCD)
E – Send Ctrl-Shift-_
L – Low log entries (line buffer)
1 – Show last 10 log entries
other – Return to connection
Press key ->
To execute the desired command, press the corresponding key on the
keyboard. You can also execute the command and avoid the menu by
pressing the [Ctrl] – [Shift] – [_] key combination quickly and pressing the
letter of the command. To quit the menu, press [Q] on the keyboard when
Instruction Manual
53