Serial Host/Tms Communications; Com 1 - Rs-485 4-Wire - Host/Tms Communications; Figure 4.4 Rs485 4-Wire, Host To A Single Multiload Iii/Rcu Iii Div2 Hardware (Recommended); Figure 4.5 Rs485 4-Wire, Host To Multiple Multiload Iii/Rcu Iii Div2 Hardware Units - Toptech MultiLoad III Installation Manual

Division 2 (div2) hardware (loaded with multiload ii+ / rcu ii+ firmware)
Hide thumbs Also See for MultiLoad III:
Table of Contents

Advertisement

CHAPTER 4– DATA COMMUNICATIONS INTERFACE

Serial Host/TMS Communications

A host/ TMS computer system can be connected to the MultiLoad III/ RCU III DIV2 Hardware in
various ways:
-
RS485 4-wire on COM 1
-
RS485 2-wire on COM 1
-
RS232 on COM1
-
Ethernet on Ethernet Port #1
4.2.3.1

COM 1 - RS-485 4-wire - Host/TMS Communications

A host/ TMS computer system can be connected to the MultiLoad III/RCU III DIV2 Hardware via
RS485 4-wire on COM 1.
The TD and RD pairs are swapped at the Host/TMS.
Host/TMS
Figure 4.4
RS485 4-Wire, Host to a Single MultiLoad III/RCU III DIV2 Hardware (recommended)
MultiLoad III/RCU III DIV2 Hardware can be multridropped on the same communication line using
a RS485 – 4 Wire on COM 1 to communicate to a host system.
Host/TMS
RS485
TDA
TDB
RDA
RDB
Figure 4.5
RS485 4-Wire, Host to Multiple MultiLoad III/RCU III DIV2 Hardware Units
28
RS485
TDA
TDB
RDA
RDB
MultiLoad III/ RCU III
MultiLoad III/RCU III DIV2 Hardware Installation Guide - Part # 6074
MultiLoad III/ RCU III
#1 COM 1
RDA
RDB
TDA
TDB
COM 1
RDA
RDB
TDA
TDB
MultiLoad III/ RCU III #n
COM 1
RDA
RDB
TDA
TDB