PSEN sl1.0p 3.1/4.1/4.2
Remove the sensor and tighten screw (c).
Align the sensor to the actuator and tighten the screws.
Adjustment
}
The stated operating distances (see Technical details: System with normal
actuator [
only apply when the safety switch and actuator are installed facing each other in paral
lel. Operating distances may deviate if other arrangements are used.
}
Note the maximum permitted lateral and vertical offset (see Lateral and vertical
offset [
Operation
Check the function of the safety switch before commissioning.
Any deviations from the properties and functions described in these operating in
structions can lead to hazardous situations.
Status indicators:
}
"Power/Fault" LED lights up green: The unit is ready for operation
}
"Safety Gate" LED lights up yellow: Actuator is within the response range
}
"Lock" LED lights up green: Magnetic guard locking device active and signal output Y32
is high
}
"Input" LED lights up yellow: There is a HIGH signal at the inputs
Operating Manual PSEN sl1.0p 3.1/4.1/4.2
1003389EN02
26], System with freemoving actuator [
11]).
CAUTION!
Contaminated surfaces can reduce the holding force of the electromagnet.
Make sure that the contact surfaces are clean.
29], under mechanical data)
22