Pilz PSEN sl-0.5n 1.1 Operating Manual

Pilz PSEN sl-0.5n 1.1 Operating Manual

Hide thumbs Also See for PSEN sl-0.5n 1.1:

Advertisement

PSEN sl-0.5n 1.1
}
PSEN sensor technology
Operating Manual-22173-EN-05

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PSEN sl-0.5n 1.1

  • Page 1 PSEN sl-0.5n 1.1 PSEN sensor technology Operating Manual-22173-EN-05...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Connection example PNOZmulti Teaching in the actuator PSEN sl-0.5n 1.1 Installation Note regarding the free-moving actuator PSEN sl-0.5fm Installing on a swing gate Installing on a sliding gate Adjustment Operation Error display through flashing codes Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 4 Contents Dimensions in mm Technical Details Order No. 570503 Technical Details Order No. 570563 Supplementary data Radio approval Safety characteristic data Order reference Safety gate system Accessories EC declaration of conformity Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 5: Introduction

    PSEN sl-0.5n 1.1 Introduction Validity of documentation This documentation is valid for the product PSEN sl-0.5n 1.1. It is valid until new document- ation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 6: Safety

    The following is deemed improper use in particular: Any component, technical or electrical modification to the product Use of the product outside the areas described in this manual Use of the product outside the technical details (see Technical details [ 23]). Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 7: Safety Regulations

    Are familiar with the basic regulations concerning health and safety / accident preven- tion, Have read and understood the information provided in this description under "Safety" Have a good knowledge of the generic and specialist standards applicable to the spe- cific application. Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 8: Warranty And Liability

    This must be considered in the operator's hazard assessment and the oper- ator must define appropriate measures to exclude manipulation. Do not remove the connector's protective cap until you are just about to connect the unit. This will prevent potential contamination. Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 9: Unit Features

    The actuator is within the response range (safety gate closed) and There is a high signal at the input S31 (control command for magnetic guard locking) The holding force of the locking magnet has been tested successfully. Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 10: Lateral And Vertical Offset

    If the safety gate is in a locked condition and is opened by force, the safety outputs will shut down. Lateral and vertical offset Max. vertical offset: 5 mm Max. lateral offset: 3 mm Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 11: Wiring

    Select a higher conductor cross section Reduce load at the outputs, e.g. with evaluation device PNOZ e1.1p Recommended cable cross sections Prerequisite: Supply voltage: 24 V Cable type: LiYY 5x0.25 mm² (79 Ohm/km) from Pilz Max. load per safety output 100 mA 500 mA Cable length 65 m...
  • Page 12: Pin Assignment

    PSEN sl-0.5n 1.1 If cable lengths greater than those stated in the table are required, please contact Pilz. Pin assignment 5-pin M12 male connector Cable colour (Pilz Function Terminal designation cable) +24 V UB Brown Output, channel1 White 0 V UB...
  • Page 13: Connection Example Pnoz S3

    PSEN sl-0.5n 1.1 The safety switch PSEN sl-0.5n 1.1 can be connected to Pilz evaluation devices, for ex- ample. Suitable Pilz evaluation devices are, for example: PNOZelog for safety gate monitoring PNOZpower for safety gate monitoring PNOZsigma for safety gate monitoring...
  • Page 14: Connection Example Pnozmulti

    Input OSSD Input OSSD Signal input Lock/Unlock Teaching in the actuator PSEN sl-0.5n 1.1 Any corresponding Pilz actuator (see Technical details: System with normal actuator [ 23], System with free-moving actuator [ 27]) is detected as soon as it is brought into the response range.
  • Page 15: Psen Sl-0.5N

    Installation of the safety switch and actuator must be concealed. Alignment errors of the guard must not adversely affect the safety function of the guard. INFORMATION Mounting brackets are available as accessories [ 31]. Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 16: Note Regarding The Free-Moving Actuator Psen Sl-0.5Fm

    The actuators enable a warped gate to be closed. A gap may occur on the gate as a result. Make sure that the gap remains small enough to exclude the possibility of reaching into the danger zone. Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 17: Installing On A Swing Gate

    Align the safety switch and mounting bracket with the actuator and tighten the screws. Installing on a sliding gate Align the actuator mounting bracket flush with the sliding gate and tighten the screws. Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 18 (Important: do not tighten the screws) Fix safety switch upright with a screw (a), close gate. Align mounting brackets, press firmly together and tighten screw (b). Remove the safety switch and tighten screw (c). Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 19: Adjustment

    "Power/Fault" LED lights up red: Error message Flashing codes for fault diagnostics are output to the "Safety Gate" or "Input" LED (see Error display through flashing codes). Remedy: Rectify fault and interrupt power supply. Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 20: Error Display Through Flashing Codes

    Once, for one second each Code for 1st digit 4 times, for one second each Code for 2nd digit Once, for one second each Code for 3rd digit 3 times, short Code for error message repeated Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 21 Check cable length and too high (cable is shorten it, if necessary (see too long) max. cable length [ 11]) Other flashing codes signal an internal error. Remedy: Change device. Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 22: Dimensions In Mm

    PSEN sl-0.5n 1.1 Dimensions in mm M12x1 Fig.: Safety switch and locking magnet 22,5 Fig.: Actuator Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 23: Technical Details Order No. 570503

    Coding level in accordance with EN ISO 14119 Design in accordance with EN ISO 14119 Classification in accordance with EN 60947-5-3 PDDB Pilz coding type Coded Transponder Frequency band 122 kHz - 128 kHz Max. transmitter output 15 mW Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 24 In accordance with the standard EN 60068-2-1/-2 Temperature range -25 - 70 °C Climatic suitability In accordance with the standard EN 60068-2-78 Humidity 93 % r. h. at 40 °C EN 55011: class A, EN 60947-5-3, EN 62061 Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 25 Connection type M12, 5-pin male connector Cable LiYY 5 x 0.25 mm2 Material Anchor plate Nickel-plated steel Base plate Anticorodal, hard anodised Actuator Anticorodal, hard anodised Max. torque setting for fixing screws 3 Nm Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 26 Actuator dimensions Height 138 mm Width 52 mm Depth 23 mm Weight of safety switch 570 g Weight of actuator 375 g Weight 950 g Where standards are undated, the 2015-04 latest editions shall apply. Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 27: Technical Details Order No. 570563

    UB is applied 1,6 s Actuator typ. 500 ms Delay-on de-energisation Actuator typ. 40 ms Actuator max. 260 ms Risk time in accordance with EN 60947-5-3 260 ms Supply interruption before de-energisation 15 ms Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 28 500 N Magnetic holding force on 500 N Magnetic holding force off 30 N Max. vertical offset 5 mm Max. lateral offset 3 mm Max. angular offset 2,5 deg Actuator 1 PSEN sl-0.5fm 1.1 Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 29 Actuator dimensions Height 138 mm Width 52 mm Depth 23 mm Weight of safety switch 570 g Weight of actuator 365 g Weight 940 g Where standards are undated, the 2015-04 latest editions shall apply. Operating Manual PSEN sl-0.5n 1.1 22173-EN-05...
  • Page 30: Supplementary Data

    2) this product must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this product not expressly approved by Pilz may void the FCC authorization to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 31: Order Reference

    European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany Operating Manual PSEN sl-0.5n 1.1...
  • Page 32 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95600621 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...

Table of Contents