PNOZ mc1p
}
Configurable, safe small controllers PNOZmulti Classic
Operating Manual-20879-EN-09

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PNOZ mc1p

  • Page 1 PNOZ mc1p Configurable, safe small controllers PNOZmulti Classic Operating Manual-20879-EN-09...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    Connecting the base unit and expansion modules ..............Commissioning ........................General wiring guidelines ......................Download modified project to the PNOZmulti system .............. Connection..........................Operation ..........................Technical details ........................Order reference ........................Product ............................. Accessories ..........................Operating Manual PNOZ mc1p 20879-EN-09...
  • Page 4: Introduction

    Introduction Introduction Validity of documentation This documentation is valid for the product PNOZ mc1p. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5 Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PNOZ mc1p 20879-EN-09...
  • Page 6: Overview

    Scope Expansion module PNOZ mc1p Jumper Unit features Application of the product PNOZ mc1p: Expansion module for connection to a base unit from the configurable control system PNOZmulti The product has the following features: Can be configured in the PNOZmulti Configurator Semiconductor outputs: –...
  • Page 7: Safety

    Safety circuits in accordance with VDE 0113 Part 1 and EN 60204-1 The expansion module may not be used for safety-related functions. The coated version of the product PNOZ mc1p is suitable for use where there are in- creased environmental requirements (see Technical details [ 14]).
  • Page 8: Disposal

    PNOZmulti Configurator's online help. Only use these functions once you have read and understood the documentations. Do not open the housing or make any unauthorised modifications. Please make sure you shut down the supply voltage when performing maintenance work (e.g. exchanging contactors). Operating Manual PNOZ mc1p 20879-EN-09...
  • Page 9: Function Description

    The online help on the PNOZmulti Configurator contains descriptions of the operating modes and all the functions of the PNOZmulti safety system, plus connection examples. Block diagram 24 V 24 V OA0 OA1 OA2 OA3 OA4 OA5 OA6 OA7 OA8 OA9 OA10 OA11OA12 OA13 OA14 OA15 Operating Manual PNOZ mc1p 20879-EN-09...
  • Page 10: Installation

    Damage due to electrostatic discharge! Electrostatic discharge can damage components. Ensure against discharge before touching the product, e.g. by touching an earthed, conductive sur- face or by wearing an earthed armband. Dimensions 94 (3.70") (1.77") Operating Manual PNOZ mc1p | 10 20879-EN-09...
  • Page 11: Connecting The Base Unit And Expansion Modules

    Please refer to the document "PNOZmulti System Expansion" for details of the number of modules that can be connected to the base unit and the module types. Operating Manual PNOZ mc1p | 11 20879-EN-09...
  • Page 12: Commissioning

    Proceed as described in the operating manual for the base unit. NOTICE For the commissioning and after every user program change, you must check whether the safety devices are functioning correctly. Connection Supply voltage Supply voltage Semiconductor outputs Operating Manual PNOZ mc1p | 12 20879-EN-09...
  • Page 13: Operation

    When the supply voltage is switched on, the PNOZmulti copies the configuration from the chip card. The PNOZmulti control system is ready for operation when the "POWER" and "RUN" LEDs on the base unit are lit continuously. Operating Manual PNOZ mc1p | 13 20879-EN-09...
  • Page 14: Technical Details

    Environmental data 773700 773705 Ambient temperature In accordance with the standard EN 60068-2-14 EN 60068-2-14 Temperature range 0 - 60 °C -25 - 60 °C Forced convection in control cabinet off 55 °C – Operating Manual PNOZ mc1p | 14 20879-EN-09...
  • Page 15 27 mm 27 mm Material Bottom PPO UL 94 V0 PPO UL 94 V0 Front ABS UL 94 V0 ABS UL 94 V0 Connection type Spring-loaded terminal, screw Spring-loaded terminal, screw terminal terminal Operating Manual PNOZ mc1p | 15 20879-EN-09...
  • Page 16 9 mm Dimensions Height 94 mm 94 mm Width 45 mm 45 mm Depth 121 mm 121 mm Weight 164 g 166 g Where standards are undated, the 2020-07 latest editions shall apply. Operating Manual PNOZ mc1p | 16 20879-EN-09...
  • Page 17: Order Reference

    Order reference Order reference Product Product type Features Order No. PNOZ mc1p Expansion module, 16 semiconductor outputs, standard 773 700 PNOZ mc1p coated ver- Expansion module, 16 semiconductor outputs, standard, 773 705 sion coated version Accessories Terminator, jumper Product type Features Order No.
  • Page 18 We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...

Table of Contents