PSEN sl1.0p 3.1/4.1/4.2
Connection example PNOZmulti
Legend:
I0
I1
I2
O1
Teaching in the actuator
PSEN sl1.0p 3.1
Any corresponding Pilz actuator (see Technical details: System with normal
actuator [
detected as soon as it is brought into the response range.
PSEN sl1.0p 4.1
Teaching in the actuator for the first time:
The first corresponding actuator to be detected by the safety switch (see Technical details:
System with normal actuator [
mechanical data) is automatically taught in as soon as it is brought into the response range.
To teach in a new actuator:
}
The actuator that is to be taught in must be brought into the safety switch's response
range as the only transponder. As soon as the actuator is detected, the "Safety Gate"
LED switches to a yellow flashing light.
}
After 20 s has elapsed, the "Safety Gate" LED switches to quick yellow flashes. Trigger
a system reset in the next 120 s by interrupting the power supply.
}
When the device is switched back on, the learning procedure is complete and the num
ber of permitted additional learning procedures is reduced by 1.
Operating Manual PSEN sl1.0p 3.1/4.1/4.2
1003389EN02
PNOZmulti
Input OSSD
Input OSSD
Signal input
Lock/Unlock
26], System with freemoving actuator [
A1
A2
grün
I0
gelb
I1
grau
I2
Ausgangs-
rot
element an
O1
PNOZmulti
26], System with freemoving actuator [
PSENslock
2
A1
7
A2
6
S11
1
S21
3
12
4
22
5
Y32
8
S31
29], under mechanical data) is
29], under
16