Electrical connexion for automatic overload regulator
Electrical connexion for automatic overload regulator
With magnetic valve closed when de-energised
With the Jumper (1) the electric re-set
bottons or pushbuttons can be activated or
disactivated. (Connexions X4-Stop and X5-
Reset)
Information
The automatic overload regulation does not
work, if the machine is not equipped with
electric re-set buttons or pushbuttons , but
the re-set buttons or pushbuttons are
activated with the Jumper (1).
Attention!
Only in case of change or retrofitting of
electric re-set buttons or pushbuttons:
If the machine is equipped with these
buttons, it must not be disactivated!
Current
All manuals and user guides at all-guides.com
Jumper (1) bridged, without
electric re-set button or pushbuttons
1
blue bridged circuit
Sensor
Magnetic-
valve
DC 104 - 12V
DC 104 - 12V
Jumper (1) non-bridged, with
electric re-set button or pushbuttons
1
Pushbutton
Buzzer
at the hopper
at the hopper
Only connected in case of
electric re-set buttons or pushbuttons
Buzzer
at the hopper