How Should I Power Off the System Before Maintenance?
Put on insulation gloves before powering off the system.
1. Turn off the single-phase power switch that controls the power supply from the remote box-type
transformer to the smart array controller.
2. Turn off the three-phase power switch that controls the power supply from the remote box-type
transformer to the smart array controller.
If the smart array controller houses one PID module, turn off the appropriate three-phase

power switch.

If the smart array controller houses two PID modules, turn off the appropriate two three-
phase power switches.
3. Turn off the DC input and output switches on the smart array controller.
If the smart array controller does not support 24 V DC input or output, skip this step.
If the smart array controller supports 24 V DC input and output, turn off the QF06 DC output
switch and QF07 DC input switch.
4. Turn off the QF01 single-phase input switch on the smart array controller.
5. Turn off the three-phase input switch on the smart array controller.
If the smart array controller houses one PID module, turn off the QF02 (or FU01) three-phase
input switch.
If the smart array controller houses two PID modules, turn off the QF02 and QF04 (or FU01
and FU02) three-phase input switches.
6. Turn off the PID switch on the smart array controller.
If the smart array controller houses one PID module, turn off the QF03 PID switch.
If the smart array controller houses two PID modules, turn off the QF03 and QF05 PID
switches.