Download Print this page

Huawei SmartACU2000B Quick Manual page 24

Smart array controller
Hide thumbs Also See for SmartACU2000B:

Advertisement

6.12
Connecting the 24 V DC Output Power Cable
You can connect one or two 24 V DC output power cables to the smart array controller that
supports 24 V DC input and output. DC output power cables are connected in the same manner.
This section describes how to connect one DC output power cable.
Port on the JX02
No.
Terminal Block
1, 2
24VOUT+
3, 4
24VOUT–
1. Prepare a cable.
2. Connect the 24 V DC
output power cable to the
JX02 terminal block.
Do not connect the cable
reversely.
3. Bind the cable.
6.13
Connecting the 24 V DC Input Power Cable
You can connect one 24 V DC input power cable to the smart array controller that supports
24 V DC input and output.
Port on the JX02
No.
Terminal Block
5
24VIN+
6
24VIN–
1. Prepare a cable.
2. Connect the 24 V DC
input power cable to the
JX02 terminal block.
Do not connect the cable
reversely.
3. Bind the
cable.
Definition
Positive terminal of the 24
V DC output power cable
Negative terminal of the 24
V DC output power cable
Definition
Positive terminal of the 24
V DC input power cable
Negative terminal of the 24
V DC input power cable
23

Advertisement

loading