Item
7-2.
9) Anti bacteria operation
Operation Mode
An Anti bacteria operation regularly performs a Hot water supply operation with the set temperature TSC_H = 75°C
and Control
(can be set with DN_0A).
Method
1) How to operate
• Pressing the [
at the set cycle and time (both can be set with the remote controller DN) to start Anti bacteria operation.
• The first Anti bacteria operation starts when press the Anti bacteria "ON" and starting time come.
• When the set temperature 75°C is reached after the Anti bacteria operation started, the set temperature remains
another 30 minutes (can be set with DN_0B).
• The priority zone determined by the outside temperature selects an operation, Hot water heat pump or hot water
supply heater.
• The hot water heat pump operation, when selected, ignores the hot water supply start condition (TTW < 38°C) and
forcibly performs a hot water operation.
• During Anti bacteria operation (Forcible hot water operation at 75°C), the hot water set temperature display is not
changed. If it is changed from the remote controller, the normal hot water set temperature will be changed.
• During a 75°C hot water supply operation with Anti bacteria,
the remote controller does not display 75°C.
• Be careful not to burn yourself; Output water may be hotter
than that displayed on the remote controller.
Related DN
DN
0A
0B
Remote
controller 0C
Remote
controller 0D
Operation flow and applicable data, etc.
] button and then the remote controller Anti bacteria "ON" changes the setting to TSC_H = 75°C
HOT WATER button set to "ON"
Anti bacteria button set to "ON"
Anti bacteria start time
75°C hot water supply operation
75°C hot water supply operation for 30 minutes
Usual hot water supply operation
(Set temperature: 40°C to 75°C)
Caution
Setting item
Anti bacteria set temperature
Anti bacteria holding time
Anti bacteria start time
Anti bacteria operation cycle
Default
75°C
30 min
22:00
7 days
64
Setting available range
65 - 80°C
0 - 60 min
0:00 - 22:00
Every day to 10 days