15. Floor drying
• This function is available only for the header remote controller.
• This function is used for drying concrete etc.
• Service personnel must operate the unit after setting the related DN code.
• Operation is not started unless All the related DN codes are set.
• Refer to the following for the settings of the related items. Please setup on the responsibility for an installer. An
unsuitable setup may cause a crack of concrete etc.
• When the operation starts, the unit operates as follows.
1
Press the [
] button and the [
seconds or longer on the top screen to display the "FIELD SETTING
MENU".
2
Press the [
FIELD SETTING MENU, then press the [
longer.
DN_14 setting start and End temperature [20-55°C]
DN_15 setting Max temperature [20-55°C]
DN_16 continuation days for every step up to Max temperature [1-7 days]
DN_17 temperature difference for every step up to Max temperature [1-10 K]
DN_18 continuation days for every step down to End temperature [1-7 days]
DN_19 temperature difference for every step down to End temperature [1-10 K]
DN_1A Continuation days in Max temperature [1-50 days]
3
Press the [
] / [
[
] / [
] button to set the value.
4
Press the [
] button. The set value is registered.
] button at same time for 4
] / [
] button to select "Floor drying" on the
] button to select DN or Data, then press the
] button for 4 seconds or
setting temperature
°C
50
49
48
47
46
45
DN_15
44
43
42
41
40
39
38
37
36
35
34
DN_17
33
32
DN_16
31
DN_14
30
29
28
27
26
25
24
:
:
1
0
0
1
2
3
4
5
171
FIELD SETTING MENU(1/2)
Test mode
Floor drying
Forced defrosting
Information input
Alarm history
DN_1A
DN_19
DN_18
6
7
8
9
10
11
12
13
14
15
lapsed days
total days
Floor drying
Code
(DN)
FIX
SET
16
17
18
19
20
21
22 Day
Data