Exchange
No.
parts name
Electrical part
1. Interface CDB (MCC-1675)
CDB
(MCC-1675)
"Detachment (Interface CDB)"
P.C.board
1).Perform the step 1-1.
For 1 minute after the power is turned off, do not disassem-
ble the inverter to prevent an electric shock.
2).Remove the fixed screws of the COVER-EP and remove
the COVER-EP. (Φ4 × 8, 3screws) [Fig. 6-1]
3).Remove all connectors connected to the Interface CDB.
[Fig. 6-2]
4).Detach the Interface CDB from 4 supporters. [Fig. 6-3]
NOTE
When removing the connectors, release the safety lock of
the housing.
"Attachment (Interface CDB)"
Attach the new Interface CDB in the reverse process of
the "Detachment (Interface CDB)".
2. Detachment (Reactor)
1) Following to work of Detachment of
2) Remove the connector of the reactor lead wire
connected to the reactor. (2 positions)
3) Remove the connector.
(Φ4 × 8, 2 screws)
3. Attachment (Reactor)
Attach the reactor in the reverse process of the
"3. Detachment (Reactor)".
Work procedure
WARNING
209
R
e
m
a
k r
s
Fig. 6-1
Screws
Screws
Screws
Screws
Fig. 6-2
CN02
CN02
CN02
CN02
CN805 CN807
CN807
CN807
CN807
CN805
CN805
CN805
(CN709)
(CN709)
(CN709)
(CN709)
CN707
CN707
CN707
CN707
CN01
CN01
CN01
CN01 CN607
CN607
CN607
CN607
CN710
CN710
CN710
CN710
CN711
CN711
CN711
CN711
CN701
CN701
CN701
CN701
Fig. 6-3
Supporters
Supporters
Supporters
Supporters
Reactor
Reactor
Reactor
Reactor lead × 2
Reactor lead × 2
Reactor lead × 2
COVER-EP
COVER-EP
COVER-EP
COVER-EP
CN604
CN604
CN604
CN604
CN603
CN603
CN603
CN603
CN602
CN602
CN602
CN602
CN601
CN601
CN601
CN601
CN600
CN600
CN600
CN600