3.3.3 Two-Module Flush Mounting

Steps:
1. Paste the installation Sticker A onto the wall. Make sure the sticker is placed leveled
via measuring with the gradienter.
2. Cave the installation hole along the solid line on Sticker A.
The suggested dimension of installation hole is 223(L)×111(W)×33(D) mm.
3. Pull out the cables, place the installation Sticker 1 into the hole, chisel 4 screw holes
accordingly.
Figure 3-18 Fix the Cover
Figure 3-19 Cave the Installation Hole