Medium-voltage switchgear/wind fixed mounted circuit-breaker switchgear up to 36 kv, extendable (172 pages)
Summary of Contents for Siemens SIMATIC NET RUGGEDCOM PSG907R
Page 1
All manuals and user guides at all-guidesbox.com Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSG907R Edition 02/2021 https://www.siemens.com...
Page 2
All manuals and user guides at all-guidesbox.com Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RSG907R Communication Ports Technical Specifications Installation Manual Certification 02/2021 C79000-G8976-1387-12...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
FAQs and manuals • Submit SRs or check on the status of an existing SR • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community...
Page 9
All manuals and user guides at all-guidesbox.com Preface Contacting Siemens viii RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
Ports designated for Redundant Network Access (RNA) – ports A/B and 5 – can be customized with a wide array of Small Form-factor Portable (SFP) transceivers offered by Siemens, making the device flexible to the needs of the redundant network application.
All manuals and user guides at all-guidesbox.com Introduction 1.1 Feature Highlights Feature Highlights Ethernet Ports • 4 x 100Base-FX fiber optic Ethernet ports • 3 x 1000Base-SX/LX SFP transceivers • Industry standard LC fiber optical connectors Rated for Reliability in Harsh Environments •...
Page 12
All manuals and user guides at all-guidesbox.com Introduction 1.2 Description POWER LED ALARM LED USB Console Port RNA Port (Port A/B) Port 5 Fiber Optic Ethernet Ports (Ports 1 to 4) Failsafe Alarm Relay Power Supply Terminal Blocks Chassis Ground Screw Figure 1.1 RUGGEDCOM RSG907R POWER LED...
All manuals and user guides at all-guidesbox.com Introduction 1.3 Required Tools and Materials Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RSG907R: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device. USB Type-B console port cable For connecting to the RUGGEDCOM ROS console interface.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Visually inspect each item in the package for any physical damage. Verify all items are included. IMPORTANT If any item is missing or damaged, contact Siemens for assistance. Installing the Device in Hazardous Locations The RUGGEDCOM RSG907R is designed to comply with the safety standards for Class I, Division 2, Zone 2 hazardous locations where concentrations of flammable gases, vapors or liquids may be present, as opposed to normal operating environments.
Page 16
All manuals and user guides at all-guidesbox.com Installing the Device 2.3 Installing the Device in Hazardous Locations Special Conditions for Safe Use Installation and use of the device in a hazardous location must meet the following special conditions for safe use: •...
All manuals and user guides at all-guidesbox.com Installing the Device 2.4 Mounting the Device Sample Hazardous Location Label The following is an example of the RUGGEDCOM RSG907R hazardous location label: Figure 2.1 Compliance Label (Example) Mounting the Device The RUGGEDCOM RSG907R is designed for maximum mounting and display flexibility.
Page 18
All manuals and user guides at all-guidesbox.com Installing the Device 2.4.1 Mounting the Device on a DIN Rail Mounting the Device To mount the device to a DIN rail, do the following: Hook the top teeth of the adapter onto the DIN rail. Note The adapter features a sliding release with a slot at the bottom for a flathead screwdriver.
All manuals and user guides at all-guidesbox.com Installing the Device 2.4.2 Mounting the Device to a Panel Removing the Device To remove the device from a DIN rail, do the following: Insert a flathead screwdriver into the slot of the sliding release and move it down.
Page 20
All manuals and user guides at all-guidesbox.com Installing the Device 2.4.2 Mounting the Device to a Panel To mount the device to a panel, do the following: Secure the mounting adapters to the top and bottom of the device using the four M4 screws included with the device.
All manuals and user guides at all-guidesbox.com Installing the Device 2.5 Connecting the Failsafe Alarm Relay Place the device against the panel and align the adapters with the mounting holes. Screw (M5 or #10-24) Panel Mount Adapter Figure 2.5 Panel Mounting Secure the adapters to the panel with M5 or #10-24 screws. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
Page 22
All manuals and user guides at all-guidesbox.com Installing the Device 2.5 Connecting the Failsafe Alarm Relay To connect the failsafe alarm relay, do the following: Insert the failsafe alarm relay terminal block into the device and tighten the screws. Figure 2.6 Assembling the Failsafe Alarm Relay Terminal Block Connect a failsafe device to the terminal block.
All manuals and user guides at all-guidesbox.com Installing the Device 2.6 Connecting Power Connecting Power The RUGGEDCOM RSG907R features two input terminals that allow the device to be powered by: • Up to one independent AC and one independent DC power source •...
Page 24
All manuals and user guides at all-guidesbox.com Installing the Device 2.6.1 Connecting AC or DC Power • Make sure a terminal block is installed in the unused port and that any wires from the secondary terminal block are properly terminated • Make sure the first power source is off before connecting (or disconnecting) a second power source If connecting a secondary power source, make sure the power source currently...
All manuals and user guides at all-guidesbox.com Installing the Device 2.6.2 Wiring Examples Connect the ground wire to the 5 POS Terminal Block Chassis/Ground Terminal chassis/ground terminal on the Negative Terminal terminal block. Positive Terminal LO DC Power supply Figure 2.9 Terminal Block Wiring Connect the Positive wire to the positive (+) terminal on the terminal block.
Page 26
All manuals and user guides at all-guidesbox.com Installing the Device 2.6.2 Wiring Examples HI Power Supply Configurations Figure 2.11 Single HI AC Power Input Figure 2.12 Single HI DC Power Input Configuration Configuration RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
Page 27
All manuals and user guides at all-guidesbox.com Installing the Device 2.6.2 Wiring Examples Figure 2.13 Dual HI AC and DC Power Figure 2.14 Dual HI DC Power Supplies Supplies RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
All manuals and user guides at all-guidesbox.com Installing the Device 2.7 Connecting the Device to the Network LO Power Supply Configurations Figure 2.15 Single LO DC Power Input Figure 2.16 Dual LO DC Power Input Configuration Configuration Connecting the Device to the Network Steps to connect the device to the network are application-specific.
Page 29
All manuals and user guides at all-guidesbox.com Installing the Device 2.7 Connecting the Device to the Network Connecting to a Local Area Network In this application, the device operates as a switch on a Local Area Network (LAN). Connect the device as follows: ...
Page 30
All manuals and user guides at all-guidesbox.com Installing the Device 2.7 Connecting the Device to the Network DAN (RUGGEDCOM RSG907R RSG907R) Figure 2.18 A PRP Network Connecting to an HSR Ring In this application, the device operates as an HSR RedBox in an HSR ring. Connect the device as follows: ...
Page 31
All manuals and user guides at all-guidesbox.com Installing the Device 2.7 Connecting the Device to the Network Connecting an HSR Ring and PRP Network In this application, the device operates as one of two HSR/PRP RedBoxes in an HSR ring that is connected to either LAN A or LAN B in the PRP network. Connect the device as follows: ...
Page 32
All manuals and user guides at all-guidesbox.com Installing the Device 2.7 Connecting the Device to the Network Port Connect To... Connect to port B of the neighboring HSR/HSR RedBox or to the HSR ring Connect to port A of the neighboring HSR/HSR RedBox or to...
Page 33
All manuals and user guides at all-guidesbox.com Installing the Device 2.7 Connecting the Device to the Network RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
All manuals and user guides at all-guidesbox.com Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RSG907R console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RSG907R.
All manuals and user guides at all-guidesbox.com Device Management 3.2 Configuring the Device Ethernet Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RSG907R console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RSG907R is https://192.168.0.1.
All manuals and user guides at all-guidesbox.com Communication Ports The RUGGEDCOM RSG907R can be equipped with various types of communication ports to enhance its abilities and performance. Ports A and B Port 5 Ports 1 to 4 Figure 4.1 Port Assignment Port Type SFP Transceiver (1000Base-SX/LX)
Page 37
RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]. IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. IMPORTANT RNA ports A and B must operate at the same speed.
SFP Transceivers The RUGGEDCOM RSG907R supports up to three Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. LEDs Each socket features an LED that indicates its link state. State...
Page 39
RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]. IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. RUGGEDCOM RSG907R...
All manuals and user guides at all-guidesbox.com Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the minimum input voltage for the power supply is provided at the power source. Hazardous Environments Power Input Voltage...
All manuals and user guides at all-guidesbox.com Technical Specifications 5.2 Failsafe Alarm Relay Specifications Failsafe Alarm Relay Specifications Hazardous Environments Maximum Switching Voltage Rated Isolation Switching Current 30 VDC 1500 V for 1 minute 80 VDC 0.3 A 30 VAC 30 VDC 5.0 kVAC between coil and contacts 1.0 kVAC...
3 dBm. To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. Data...
All manuals and user guides at all-guidesbox.com Technical Specifications 5.6 Mechanical Specifications Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings. Non-condensing. Mechanical Specifications Weight 2.4 kg (5.3 lbs) Ingress Protection IP40 Enclosure...
Page 44
All manuals and user guides at all-guidesbox.com Technical Specifications 5.7 Dimension Drawings 38.1 163.12 Figure 5.2 Panel Mount Dimensions 162.72 Figure 5.3 DIN Rail Mount Dimensions RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
Page 45
All manuals and user guides at all-guidesbox.com Technical Specifications 5.7 Dimension Drawings RUGGEDCOM RSG907R Installation Manual, 02/2021, C79000-G8976-1387-12...
All manuals and user guides at all-guidesbox.com Certification The RUGGEDCOM RSG907R device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. Approvals This section details the standards to which the RUGGEDCOM RSG907R complies. 6.1.1 This device meets the requirements of the following Canadian and U.S.
All manuals and user guides at all-guidesbox.com Certification 6.1.2 CSA/Sira • ANSI/UL 60079-15:13 Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Type of Protection "n" The device is marked with a CSA symbol that indicates compliance with both Canadian and U.S. requirements. It is specifically approved for use in Division 2 and Zone 2 hazardous locations with the following markings: •...
Electromagnetic compatibility of multimedia equipment – Emission requirements The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.6 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.7...
Republic of Korea (South Korea) as a Class A product in a commercial, industrial or business environment. R-REM-S14-RSG907R A copy of the KC Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
All manuals and user guides at all-guidesbox.com Certification 6.2 EMC and Environmental Type Tests • EN50121-4 Railway applications – Electromagnetic Compatibility – Emission and Immunity of the Signaling and Telecommunications Apparatus • EN50121-3-2 Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus •...
Page 52
All manuals and user guides at all-guidesbox.com Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels Pulse Magnetic Field Enclosure 300 A/m 61000-4-9 Ports Voltage Dips and Interrupts AC Power 30% for 0.5 Cycles 61000-4-11 Ports 60% for 5 Cycles 100% for 250 Cycles Mains Frequency Voltage...
Page 53
All manuals and user guides at all-guidesbox.com Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels IEEE 1613 Oscillatory Signal Ports 2.5 kV Common Mode @ 1 MHz DC Power Ports 2.5 kV Common Mode @ 1 MHz 1 kV Differential Mode @ 1 MHz IEEE 1613 HV Impulse...
Page 54
All manuals and user guides at all-guidesbox.com Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...