Resetting The Intermediate Meter - Borger STE-RSM2 Operating Manual

Reversing control unit
Table of Contents

Advertisement

Fault message:
"Fuse, PLC outputs"
The following applies to
versions with a
frequency converter:
"Fuse, macerator
frequency converter"
5.5

Resetting the intermediate meter

62
Possible causes
Short circuit / overcurrent at
the PLC,
circuit breaker set to 0
Short circuit / overcurrent at
the frequency converter,
circuit breaker set to 0
For this work step, the set-up user password is required or you
have to be logged in as set-up user already.
Select the Setting menu (4).
Select the Operating hours submenu (K).
Select Reset in order to reset the intermediate meter to 0.
www.boerger.de / www.boerger.com
Remedial action
• Rectify any causes for short circuit /
overcurrent, if applicable
• Reactivate the circuit breaker
• Rectify any causes for short circuit /
overcurrent, if applicable
• Reactivate the circuit breaker
BA-STE-RS, 26.09.2014