Normal Operation - Borger STE-RSM2 Operating Manual

Reversing control unit
Table of Contents

Advertisement

5.2

Normal operation

56
Select whether you would like time-dependent reversing to be
triggered in order to prevent blockages by touching the field
Automatic reversing On (3.1) or Off, independent of the
current consumption of the drive.
This requires time settings for
automatic reversing in the Setting
menu, submenu 4.1.
Upon completion of all preliminary tasks, please select the
operating mode:
– Automatic operation (3) for controlled operation
according to the pump control unit
– Manual operation for uncontrolled operation
For Manual operation: Press the green start button. The
motor of the connected macerator starts up.
During Automatic operation, the motor of the connected
macerator starts according to the signals of the pump control
1)
unit
.
During trouble-free operation, the indicator light of the start-stop
button (8) is lit during Manual operation.
During automatic operation, the yellow LED indicator lamp
Autom. Start-up warns of a potential automatic start of the
macerator.
1)
External control unit when no extension of the reversing control unit for
controlling the pump has been supplied
Note
After the motors have started, you can manually trigger a
reversing process by touching the start button both during
manual and automatic operation, e.g. in order to prevent a fault
switch-off when the local operating person has identified an
increased current consumption.
www.boerger.de / www.boerger.com