Transportation, As-delivered Condition, Storage, Installation
4.4

Installation

4.4.1

Positioning

BA-STE-RS, 26.09.2014
Prior to commissioning, make sure that you are using the
correctly preset control unit for your macerator.
Notice
Do not commission the macerator using a control unit without
the appropriate settings.
Otherwise, your macerator may not function and damage to the
unit, e.g. as a result of incorrect limit definitions or impermissible
changes of direction of rotation, cannot be excluded.
Notice
Risk of damaging the electronic components!
Protect the STE-RS control unit from heat, cold, moisture and
frost.
The control unit may not be exposed to extreme weather
conditions which cause the values to fall below or exceed the
limits of the components.
Choose the location in which the control unit is to be installed
in such a way that the lateral ventilation openings (if
applicable, e.g. in the version with frequency converter)
remain uncovered. The unimpeded inlet and outlet of air must
be guaranteed.
Ensure that the protection from heat, cold, moisture and frost
is sufficient.
Choose the location in which the unit is to be installed so that
the control unit remains accessible at all times. The service
space required for work on the control unit is 1.0 x 1.0 m
(3.28 x 3.28 ft).
In respect of the macerator and any other components,
observe the service space as described in the relevant
operating manual.
www.boerger.de / www.boerger.com