Adjusting The Control Parameters - Borger STE-RSM2 Operating Manual

Reversing control unit
Table of Contents

Advertisement

Operation
5.1.5

Adjusting the control parameters

BA-STE-RS, 26.09.2014
Activate Manual operation by touching the relevant field (2)
until activation is signaled by the field being highlighted.
Continuously touch the Forwards field (2.2).
Check the direction of rotation of the motor as described in the
operating manual of the macerator.
Switch the motor back off by releasing the Forwards field
(2.2).
For an optional extended control unit design, check the
function and direction of rotation of all other components
correspondingly. When checking the direction of rotation of a
connected rotary lobe pump, ensure that the pump runs
without pumped medium for a very short time only, as
described in the operating manual for the rotary lobe pump.
If required, have the direction of rotation of the drives
corrected by a qualified electrician (by switching the phase
conductors) after the control unit has been shut down via the
main switch.
Notice
Risk of material damage due to impermissible changes to
limit values. The nominal current settings of the motor at the
motor protection switch or at the frequency converter must not
be changed. Non-compliance may lead to motor damage at the
macerator.
Note
Börger GmbH recommends prior consultation with Börger
customer service in all cases in which an adjustment of settings
appears necessary.
For parameter changes, the set-up user password is required or
you have to be logged in as set-up user already.