Reversing control unit
Table of Contents

Advertisement

Product Description
3.1.8

Menu navigation

BA-STE-RS, 26.09.2014
Main menu
1.1 Current date and time display
1.2 Operating status display
System ready / System not ready
1.3 Operating mode activation fields:
Manual operation (without regulation) or
automatic operation (regulation according to the
pump control unit), highlighted in dark gray when
selected
1.4 Current value display:
— Current consumption of the macerator,
actual value and limit
— Number of reversing processes related to
overcurrent within 10 minutes before a fault
message is generated;
Act. value = actual reversing processes
already performed and
Maximum = maximum number of reversing
processes within 10 minutes stored
1.5 Reversing active:
This display appears while reversing processes
are being performed.
1.6 Automatic reversing On/Off: Activation fields for
switching automatic, time-dependent reversing
processes on and off (independent of the current
consumption of the drive), highlighted in dark
gray when selected
1.7 Operation:
Touching the field leads back to the main menu
from a submenu
1.8 Reset:
Touching the field resets the control unit back to
the operation status after a fault has been
reported