Faults; Reversing When The Current Consumption Is Exceeded - Borger STE-RSM2 Operating Manual

Reversing control unit
Table of Contents

Advertisement

5.4

Faults

5.4.1

Reversing when the current consumption is exceeded

58
If the current consumption of the motor of the connected
macerator exceeds the preset limit, the reversing process is
initiated.
The motor alternatingly runs forwards and backwards for short
sequences, according to the preset duration and number.
The display shows Reversing active (1.5).
Upon completion of a reversing process, the motor of the
macerator is reset to normal operation.
If the fault could not be rectified, the control unit repeats the
reversing process as many times as are stored as Maximum
under Number of reversing processes for 10 minutes.
The display (1.4) shows the number of reversing processes
permitted within 10 minutes, the number of reversing processes
already performed within this time frame as well as the current
consumption of the macerator.
If the current consumption of the macerator motor still exceeds the
preset limit after completing the Maximum number of automatic
reversing processes within ten minutes, the control unit switches
off the motor of the macerator. The red LED indicator lamp Fault
lights up.
In the Faults menu, the message Fault, number of reversing
processes reached appears.
www.boerger.de / www.boerger.com
Operation