Electrotechnical Data; Ambient Conditions Of Ste-Rs Control Unit; System Limits - Borger STE-RSM2 Operating Manual

Reversing control unit
Table of Contents

Advertisement

Product Description
3.3.2

Electrotechnical data

3.3.3

Ambient conditions of STE-RS control unit

3.3.4

System limits

BA-STE-RS, 26.09.2014
Voltage input:
Control voltage:
Frequency:
No. of phases:
Nominal current:
Mains fuse required:
(When a pump is connected: see specifications in circuit diagram.)
All phases (3P/N/PE), including the neutral conductor, must be
properly connected and fully functional.
The residual current device for electric shock protection must be
AC/DC sensitive (RCD, type B).
Ambient temperature:.......................0 to 40 °C (32 to 104 °F)
Storage temperature:........................-15°C to 40°C (5°F to 104 °F)
Operating temperature:....................20°C (68°F)
Relative humidity:..............................up to 90%
The basic limits of the macerator and any further components are
contained in the operating manuals for these components.
For the standard version of the STE-RS control unit (macerator
with control unit), the following values must be observed.
www.boerger.de / www.boerger.com
400 V AC
24 V
50 Hz
3P/N/PE
Corresponds to the nominal current of
the motor of the connected macerator
as stated on the nameplate (see also
chapter 3.3.4);
when a pump is connected: control unit nominal
current = (macerator nominal current + pump
nominal current) x 0.8, see nameplate
16 A
with 1.5 to 3.0 kW drive
25 A
with 4.0 to 5.5 kW drive
35 A
with 7.5 to 11 kW drive
50 A
with 15 kW drive
63 A
with 18.5 kW drive
80 A
with 22 kW drive
100 A
with 30 kW drive