4.4.2
Installing the control cabinet
44
Transportation, As-delivered Condition, Storage, Installation
When a complete macerating system on a base frame is
delivered, and in the case of mobile macerating systems, the
STE-RS control unit is usually supplied readily mounted on the
mounting frame and ready for operation.
A second person is required for installing a control unit, which is
supplied separately.
The control unit is wrapped in packaging material to protect it from
dirt and scratching.
●
Completely remove all the packaging material before
commissioning.
Four fixing bores are located on the rear panel of the control
cabinet.
●
Take any necessary precautions to ensure that the sensitive
electronic components are not damaged during installation.
●
Install the control unit with four suitable screws and washers
on a straight, dry wall using suitable dowels or a suitable
holding frame. For installation on a holding frame, use force-
locked screw-locking devices, especially with mobile systems.
●
Align the control cabinet carefully using a spirit level.
Compensate for uneven walls with washers, if necessary, so
that the control cabinet is not tilted forward or backward
mounted.
www.boerger.de / www.boerger.com
BA-STE-RS, 26.09.2014