Lbb 3511/00 Dip-Switch S12 And S13 Settings - Bosch Digital Congress Network Installation And Operating Manual

Hide thumbs Also See for Digital Congress Network:
Table of Contents

Advertisement

Digital Congress Network | Installation and Operating Manual | Chapter 5 - Control using PC

5.4.2 LBB 3511/00 DIP-switch S12 and S13 settings

For location details see
FIG 5-5
DIP-switch S12
:
Assign cards digital input (0 - 31)
DIP-switch S13
:
Assign cards 1/O (Input/Output) address (04E0 HEX)
DIP-switch S12
IP switches to define the card's 'digital input'.
Table 5-2: DIP-switch S12
LBB 3511/00 PC-card for Multi-CCU systems
SW 1
ON
Chairman priority tone ON (default)
OFF
Chairman priority tone OFF
SW 2
OFF
Reserved for card's Master Address (IMPORTANT: must NOT be changed)
SW 3
OFF
Reserved for card's Master Address (IMPORTANT: must NOT be changed)
SW 4
OFF
Reserved for card's Master Address (IMPORTANT: must NOT be changed)
SW 5
OFF
Reserved for card's Master Address (IMPORTANT: must NOT be changed)
SW 6
ON
Active microphones and requests will be permanently switched OFF if the
priority function of the chairman's unit is activated.
OFF
Active microphones will be switched OFF temporarily if the priority
function of the chairman's unit is activated (default)
SW 7
OFF
Reserved for card's Master Address (IMPORTANT: must NOT be changed)
SW 8
OFF
Reserved for card's Master Address (IMPORTANT: must NOT be changed)
8 7 6 5 4 3 2 1
S12
ON
Bosch Security Systems | 04-2003 | 3922 988 43318 en
DIP-switch S13
Table 5-3: DIP-switch S13
IMPORTANT:
DO NOT CHANGE
Get other manuals https://www.bkmanuals.com
LBB 3511/00 PC-card for Multi-CCU systems
DIP-switches to define the cards I/O address (default: 0200 HEX)
I/O address
0100 HEX
0140 HEX
SW 1
OFF
OFF
SW 2
OFF
OFF
SW 3
ON
ON
SW 4
OFF
OFF
SW 5
OFF
ON
SW 6
OFF
OFF
SW 7
OFF
OFF
SW 8
OFF
OFF
Actual address settings DIP switch S13
Address (0100HEX)
Address (0140HEX)
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
S13
ON
S13
DIP-SWITCH S13
DIP-SWITCH S13
Address (0280HEX)
Address (0200HEX)
(default)
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
S13
S13
ON
DIP-SWITCH S13
DIP-SWITCH S13
NOTES:
1.
Available addresses (HEX): 0100, 0140, 0200 (default), 0280.
These addresses must be set with the DIP-switches and in the Config.sys file of the OS/2
PC.
2.
Available interrupts IRQ: 3, 4, 5, 7, 9, 10 (default) and 12.
NOTE: These interrupts must be set in the Config.sys file of the OS/2 PC.
en | 5-5
0200 HEX
0280 HEX
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
LBB 3511/00 PC Card for Multi-CCU Systems