13.5.4 Combined units

Delegate microphone with transmission link to interpreter headphone
Delegate microphone with transmission link to delegate headphone
Delegate microphone with transmission link to auxiliary output
2
Interpreter microphone with transmission link to interpreter headphone
Interpreter microphone with transmission link to delegate headphone
Interpreter microphone with transmission link to auxiliary output
Typical frequency response
Front-to random sensitivity index
Rated equivalent sound pressure level
due to inherent noise
Total harmonic distortion at overload
Crosstalk attenuation

13.5.5 System Electrical and Electro-acoustical characteristics

Nominal input level
Overload input level
Automatic gain reduction at Overload
input level (not applicable to
PA-floor output)
Automatic gain reduction with
-
Operator master gain control
Loudspeaker gain control

13.5.6 System environmental conditions

Temperature range:
Transport:-20 to +55 °C (-65 to 131° F)
Operational:+5 to +45 °C (+41 to 113° F)
Relative humidity:95% max.
Safety:acc. to EN 60065, and: acc. to CAN/CSA E65-94 and UL6500 (UL and cUL) for LBB
3500/xxD, LBB 4106/00D and LBB 3508/00D
EMC emission:acc. to harmonized standard EN 55013 (1988)and FCC rules (part 15) complying
with the limits for a class A digital device.
EMC immunity:acc. to harmonized standard EN 55020 (1987)
EMC approvals:affixed with the CE mark, EC directive 89/336 EEC
Shock resistance:acc. to IEC 86.2.29 Eb
Vibration resistance:acc. to IEC 68.2.6 Fc, procedure A
Bosch Security Systems | 04-2003 | 3922 988 43318 en
:
125 Hz (-8 dB) - 14.000 Hz (-8 dB)
:
> 4.6 dB
:
< 25 dB (A)
:
< 1 %
:
> 80 dB
:
85 dB SPL
:
110 dB SPL
:
30 dB (interpretation channels)
18 dB (loudspeaker channel)
:
3 dBm (2 microphones on)
6 dBm (4 microphones on)
:
15 x 1.5 dB and OFF (Mute)
:
14 x 1.5 dB and OFF
Get other manuals https://www.bkmanuals.com
NOTE:
The maximum operational temperature for ALL operational contribution units
with LC-display is 40°C. The maximum operational temperature for the Ext. Power supply
unit LBB 4106/.. is +40°C.
Safety Standards for North America
Approvals (CSA, C and USA):CAN/CSA E65 -94 UL 6500

13.5.7 Interface data

LBB 3500/.. Central Control Unit
Line in/outputs:-18 dBV/ +12 dBV* (nominal/maximum)
Recorder input/output:-33 dBV/ -3 dBV(nominal/maximum)
* -12 dBV / +18 dBV when used as symmetrical output..
LBB 3508/00 Audio Media Interface Unit
Symmetrical line outputs (XLR)
Channels 0 up to 11 (Interpretation):+1 dBV/1 dBV (nominal/maximum)
Channels 12 and 14 (PA):-8 dBV/ +22 dBV
Channel 13 (del. loudspeaker):+1 dBV/ +13 dBV
Asymmetrical line outputs (Cinch)
Channels 0 pot 11 (Interpretation) :-10 dbV/ -10 dBV (nominal/maximum)
Channels 12 and 14 (PA):-19 dBV/ +11 dBV
Channel 13 (del. loudspeaker):-10 dBV/ +2 dBV

13.5.8 Mains supply

LBB 3500/05 (D), LBB 3500/15 (D),
:
LBB 3500/35 (D), LBB 4106/00 (D),
LBB 3508/00 (D)
NOTE:
Upon delivery
:

13.5.9 Power consumption (nominal)

LBB 3500/05 (D)
:
LBB 3500/15, LBB 3500/35 (D)
:
LBB 4106/00 (D)
:
LBB 3508/00 (D)
:
en | 13-10
105 - 115 - 125 - 220 - 230 - 240 V
+ 6% / -10 %
230 V
125 V (D-versions)
175 W
350 W
350 W
175 W