DIP Switch S12
8 7 6 5 4 3 2 1
2
S12
ON
1
S12
8 7 6 5 4 3 2 1
S12
ON
8 7 6 5 4 3 2 1
S13
ON
S13
2
DIP Switch S13
FIG 4-6 Multi-CCU PCB for CCU LBB 3500/35 (DIP-switch and jumper settings)
Bosch Security Systems | 04-2003 | 3922 988 43318 en
Address Settings 0 to 31
Select a different address for every CCU
installed. Use switch positions 4 to 8 only)
Switches 1,2 and 3 not available for selection
(DO NOT CHANGE)
5
6
D1 D2 D3
D4 D5 D6
X31A
IC200
X10
Input/Output (I/O) settings (04E0 HEX)
8 7 6 5 4 3 2 1
Default settings DO NOT CHANGE
NOTE: S13 is shown in its default position
ON
Get other manuals https://www.bkmanuals.com
Jumper X32
3
(NOT PLACED)
X11
X29
IC2
IC1
X32
1
X25
X24
4
!
Jumper X24
(PLACED)
DIP-Switch S12
The decimal value assigned to each DIP-switch is as follows:
SW 8
ON = 1
LSB (Least Significant Bit)
SW 7
ON = 2
SW 6
ON = 4
SW 5
ON = 8
SW 4
ON = 16 MSB (Most Significant Bit)
SW 3
OFF *
SW 2
OFF *
SW 1
OFF *
*DO NOT CHANGE !
EXAMPLE SETTING (Address 25)
8 7 6 5 4 3 2 1
S12
ON
en | 4-10