19: Output B voltage calibration
Interface
Parameter 2: it always shows OP.V as output voltage*.
Parameter 3: it shows the internal measurement value of the output
B voltage, and you can calibrate it by pressing Up or Down according
to the measurement from an external voltage meter. The calibration
Setting
result will be effective by pressing Enter. The calibration range is limited
within +/-9V. This function is normally used for parallel operation.
*It will display number 1 under
20: Output C voltage calibration
Interface
Parameter 2: it always shows OP.V as output voltage.
Parameter 3: it shows the internal measurement value of the output
C voltage, and you can calibrate it by pressing Up or Down according
to the measurement from an external voltage meter. The calibration
Setting
result will be effective by pressing Enter. The calibration range is limited
within +/-9V. This function is normally used for parallel operation.
*It will display number 2 under
21: Charging current setting
Interface
Parameter 2: it always shows CHG as charging current.
Setting
Parameter 3: The setting range is from 1A to 12A and the default value
is 1A.
32
to represent the output B voltage.
to represent the output C voltage.