Installing The Front Mounting Front Perc Module - Dell EMC PowerEdge E75S Series Installation And Service Manual

Table of Contents

Advertisement

2. Follow the procedure listed in the
3.
Remove the air
shroud.
4.
Remove the drive backplane
5.
Remove the cooling fan cage
6. Disconnect the PERC cable from the system board connector, observe the cable routing.
Steps
1. Using a Phillips #2 screwdriver, loosen the captive screws on the front PERC module.
2. Pull the front PERC module to disengage from the connector on the drive backplane.
3. Llift the front PERC module out of the system.
NOTE:
The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 86. Removing the front mounting front PERC module
Next steps
1.
Replace the front mounting front PERC

Installing the front mounting front PERC module

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the air
shroud.
4.
Remove the drive backplane
5.
Remove the cooling fan cage
6. Route the cable properly to prevent the cable from being pinched or crimped.
Steps
1. Align the front PERC module at an angle until the tray touches the slot in the system.
2. Press the front PERC module connector with the connector on the drive backplane until firmly seated.
3. Using a Phillips #2 screwdriver, tighten the captive screws on the front PERC module.
Before working inside your
cover.
assembly.
module.
Safety
instructions.
Before working inside your
cover.
assembly.
system.
system.
Installing and removing system components
89