Main Settings (Welding Parameters) - Linde BOC Smootharc Advance MIG 425R Operating Manual

Table of Contents

Advertisement

6.4 Main Settings (Welding parameters)

MIG/SYN Display
1. Rotate left knob to set
the welding current and plate
thickness, and the voltage will
match automatically.
3. Rotate right knob to set
the parameter value.
Note: When adjusting the welding current, the corresponding plate thickness and wire feeding speed will be
displayed in the screen. When the arc length is adjusted, the voltage will be fine tuned automatically.
TIG Display
1. Rotate left knob to set
the welding current.
Note: During welding, the screen displays real-time current and voltage,
and the unit is red.
In the Home Screen, select the welding mode through the left knob,
rotate the right knob, select Main SET, and then press the right to
enter this screen. The Main SET/Welding screen of each welding
mode is different, as shown in the figure below.
2. Short press right knob to switch
welding voltage/inductance.
L
4. Long press (5 Seconds)
left knob to call out
JOB storage dialog box.
2. Rotate right knob to set
the post-gas flow time.
(Reserve)
BOC Smootharc Advance III MIG 425R & 555R Operating manual
MIG/Manual Display
1. Rotate left knob to set
the wire feed speed
in m/min.
3. Rotate right knob to set
the parameter value.
MMA Display
1. Rotate left knob to set
the welding current.
2. Short press right knob to
switch welding voltage/
inductance.
L
4. Long press (5 Seconds)
left knob to call out
JOB storage dialog box.
2. Rotate right knob to set
the ARC force.
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Boc smootharc advance mig 555r

Table of Contents