Recommended Welding Parameters For Mig/Mag - Linde BOC RAPTOR 200 MIG Operating Manual

Table of Contents

Advertisement

6.7 Recommended Welding Parameters for MIG/MAG
Argoshield Light
Indicative
Welding Parameters
Material thickness (mm)
Welding position
Wire diameter (mm)
Current (amps)
Voltage (volts)
Wire feed speed (m/min)
Gas rate flow (L/min)
Travel speed (mm/min)
Stainshield
(Aus)
or Stainshield Light
Indicative
Welding Parameters
Material thickness (mm)
Welding position
Wire diameter (mm)
Current (amps)
Voltage (volts)
Wire feed speed (m/min)
Gas rate flow (L/min)
Travel speed (mm/min)
Dip Transfer
1–1.6
2
Horizontal /
Horizontal /
Vertical
Vertical
0.8–0.9
0.8–0.9
45–80
60–100
14–16
16–17
3.5–5.0
4.0–7.0
15
15
350–500
350–500
(NZ)
Dip Transfer
4
6
Horizontal /
Horizontal /
Vertical
Vertical
0.9–1.0
0.9–1.0
100–125
120–150
17–19
18–20
5.0–6.5
6.0–7.5
15
15
400–600
280–500
3
4
Horizontal /
Horizontal /
Vertical
Vertical
0.8–0.9
0.9–1.0
80–120
80–150
16–18
16–18
4.0–7.0
4.0–7.0
15
15
320–500
280–450
8
Horizontal /
Vertical
0.9–1.0
120–150
18–20
6.0–8.0
18
280–450
Spray
Transfer
3
Horizontal
0.8
160–180
23–25
7.5–9.0
15
800–1000

Advertisement

Table of Contents
loading

Table of Contents