Download Print this page

Bahco TAWM1412M Original Instructions Manual page 5

Standard and slim electronic torque-angle wrench with memory

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
USER INSTRUCTIONS
BATTERY
CONDITION
FIGURE 1
USB
DATA
CONNECTOR
STORAGE
ALERT
Install fresh Alkaline "AA" cells into handle of wrench.
WRENCH POWER ON SEQUENCE
Note: Do not turn on wrench while torque is applied, otherwise torque zero offset will be incorrect
and wrench will indicate a torque reading when torque is released. If this occurs, re-zero wrench by
momentarily pressing POWER button while wrench is on a stable surface with no torque applied.
1. Turn On Wrench.
While holding wrench still, press POWER button. BAHCO logo will be displayed followed by torque and
angle re-zeroing screens (if angle mode has been previously selected). If real-time-clock has not been
set, date and time entry screens are displayed (see Advanced Configuration section for entering date
and time). After entering date and time or if time has been previously set, target TORQUE or ANGLE
screen will now be displayed (depending on previous measurement mode selected).
2. Select Measurement Mode.
Toggle between target TORQUE and ANGLE screens by repeatedly pressing ENTER button.
STD
TORQUE AND/OR
ANGLE DISPLAY
PROGRESS
MODE
ON/OFF AND
LIGHTS
COUNT
PROGRESS
UNITS AND
LIGHTS
PRESET ENTRY
INCREMENT
MODE SELECT AND
RE- ZERO
BUTTON
MENU ENTRY BUTTON
BUTTON
DECREMENT
LCD BACKLIGHT
BUTTON
AND PEAK
BUTTON
TORQUE/ANGLE
RECALL BUTTON
PROGRESS LIGHTS
Yellow:
First light indicates 40% of
target torque or angle
reached, Second
indicates 60% of target
reached, Third indicates
AUDIBLE
80% of target reached.
Green:
ALERT
Indicates target torque or
angle reached.
Red:
Indicates exceeded
torque or angle target
plus 4% or exceeded
maximum Preset target.