Bahco TAWM1412M Original Instructions Manual page 12

Standard and slim electronic torque-angle wrench with memory

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
TAWM SERIES
3. In Show Data screen, scroll through each stored data record by pressing UP/DOWN buttons.
Example:
0002 = Show Data List Counter: TQ = Peak torque value
0001 = Show Data List Counter: TQ = Peak torque value: ANG = Peak angle value
4. Pressing ENTER button while on Show Data screen returns to main menu.
STD
SLIM
Note: A maximum of 1500 data records can be stored. Memory full icon will be displayed when
full and no more data is stored until memory is cleared.
DELETING STORED TORQUE AND ANGLE DATA
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Highlight CLEAR DATA menu selection using UP/DOWN buttons then press ENTER button to
display CLEAR ALL DATA screen.
3. In CLEAR ALL DATA screen, highlight YES menu selection to delete all stored data, or NO menu
selection to exit without deleting data.
4. Press ENTER button after making selection.
Note: If wrench is Locked (see Preset Lock in Advanced section), Clear Data function is disabled.

Advertisement

loading

This manual is also suitable for:

Tawm series