Bahco TAWM1412M Original Instructions Manual page 26

Standard and slim electronic torque-angle wrench with memory

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
TAWM SERIES
3. Use UP/DOWN buttons to highlight menu selections.
4. Press ENTER button while EXIT menu selection is highlighted to return to Configure menu.
STD
SETTING TARGET TOLERANCES
This function will allow user to set plus and minus tolerances for torque and angle targets.
Note: These tolerances are used for manual modes only. Preset tolerances are defined by Mini-
mum and Maximum values.
1. From Mode Setup menu, use UP/DOWN buttons to highlight tolerance selection to setup (TQ-%,
TQ+%, ANG-% ANG+%) then press ENTER button.
2. Tolerance screen is displayed.
3. Use UP/DOWN buttons to change tolerance value. Range is 0 to 10% ( factory default for minus
tolerance is 0% and 4% for plus tolerance).
4. Press ENTER button to accept selection and exit to Mode Setup menu.
STD
Note: Green progress lights turn on at target minus -% TOL.
Note: Red progress lights turn on above target plus +% TOL.
Note: Plus tolerance is added to minimum Preset value to define initial maximum value when a
Preset is first added.
ENABLE/DISABLE TORQUE THEN ANGLE MODE
This function will allow user to enable or disable Torque THEN Angle Mode.
1. From Mode Setup menu, use UP/DOWN buttons to highlight THEN DISABLED (factory default)
selection then press ENTER button.
2. TQ THEN ANGLE enable/disable screen is displayed.
3. Use UP/DOWN buttons to select ENABLE or DISABLE selection.
4. Press ENTER button to accept selection and exit to Mode Setup menu.