tolerance (default 0%, see MODE SETUP in Advanced Configuration section). MINIMUM ANGLE can be
set from 0 to TARGET ANGLE by pressing UP/DOWN buttons. Once desired minimum angle value has
been set, press ENTER button.
5. MAXMUM ANGLE screen is displayed next. MAXIMUM ANGLE is angle value above which red progress
lights turn on. Initial MAXIMUM ANGLE value will be TARGET ANGLE plus positive angle tolerance (de-
fault 4%, see MODE SETUP in Advanced Configuration section). MAXIMUM ANGLE value can be set to
any value greater than TARGET ANGLE by pressing UP/DOWN buttons. Once desired value has been
set, press ENTER button.
6. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press UP/
DOWN buttons to increment/decrement batch count. Mode Count increments each time target angle is
reached if a batch count of zero is entered. Mode Count decrements if a non-zero batch count is entered
and resets to batch count value when count reaches zero. Once desired batch count value has been set,
press ENTER button.
7. PSET target screen is displayed labeled with next available PSET number from 01 to 50.
8. To enter additional angle presets, repeatedly press ENTER button until target angle screen is displayed and
repeat steps above.
STD
SLIM
EDITING A PRESET
Edit PSET function gives user ability to edit stored PSETS on wrench.
1. From Preset screen to be edited, press and hold UNITS button for 3 seconds.
2. CHANGE PRESET screen is displayed.