  • Page 1 TAWM SERIES STANDARD AND SLIM ELECTRONIC TORQUE-ANGLE WRENCH WITH MEMORY Original Instructions...
  • Page 2: Important Safety Instructions

    ASME battery life requirement of 10 hours cracks. alternating peak torque/angle on release of continuous operation. • Replace fasteners with rounded Contact BAHCO if a translation is needed. torque corners. • Peak Recall - display last peak torque or peak DEFAULT AUTO SHUT-OFF •...
  • Page 3: Torque Mode

    1. Turn On Wrench. While holding wrench still, press POWER button. BAHCO logo will be displayed followed by torque and Note: When date and time is set for first time, In-Service date is also set and is used for calculating angle re-zeroing screens (if angle mode has been previously selected).
  • Page 4: Data Download

    TAWM SERIES wrench must be placed on a stable surface. If ENTER button is pressed before two seconds to change to torque only mode, angle zero process is skipped. 1. Set target. Use UP/DOWN buttons to change target ANGLE value.
  • Page 5 TAWM SERIES MAIN MENU Main menu displays wrench operational information. 1. From target torque or angle screen, press and hold ENTER button for 3 seconds. 2. Use UP/DOWN buttons to highlight menu selection then press ENTER button. Menu Selections: EXIT - Exits Main menu and returns to target screen.
  • Page 6 TAWM SERIES When length of an offset (or sum of head minus offset for interchangeable head) is negative, maximum Example: fastener target is limited by following formulas: 0002 = Show Data List Counter: TQ = Peak torque value 0001 = Show Data List Counter: TQ = Peak torque value: ANG = Peak angle value 4.
  • Page 7 TAWM SERIES Note: If wrench is Locked (see Preset Lock in Advanced section), Clear Data function is disabled. Note: If wrench is Locked (see Preset Lock in Advanced section) Clear count function is disabled. LANGUAGE 1. To select the language menu, press the ENTER button while LANGUAGE is highlighted then highlight the desired language and press the ENTER button.
  • Page 8 TAWM SERIES 6. MAXIMUM TORQUE screen is displayed next. MAXIMUM TORQUE is torque value above which red progress lights turn on. Initial MAXIMUM TORQUE value will be TARGET TORQUE value plus positive torque tolerance (default 4%, see MODE SETUP in Advanced Configuration section).
  • Page 9: Editing A Preset

    TAWM SERIES tolerance (default 0%, see MODE SETUP in Advanced Configuration section). MINIMUM ANGLE can be 3. Highlight EDIT selection using UP/DOWN buttons then press ENTER button. set from 0 to TARGET ANGLE by pressing UP/DOWN buttons. Once desired minimum angle value has 4.
  • Page 10: Advanced Settings

    TAWM SERIES SLIM Note: Pressing ENTER button while EXIT menu selection is highlighted will exit without deleting PSET. Note: When a PSET is deleted, all other stored PSET’s will retain their original PSET numbers. When a new PSET is entered, it will be assigned first available PSET number in sequence.
  • Page 11 TAWM SERIES SETTING SLEEP TIME KEY BEEP SETUP This function will allow user to set interval wrench enters power-down state following last applied This function will allow user to enable or disable audio feedback when a button is pressed. torque or button press.
  • Page 12 TAWM SERIES 2. AUTO BACKLIGHT screen is displayed. VIBRATOR CONFIGURATION 3. Use UP/DOWN buttons to highlight ENABLE (factory default) or DISABLE selection. This function will allow user to configure vibrator for On or Off when target is reached for preference 4.
  • Page 13: Advanced Configuration

    TAWM SERIES ADVANCED CONFIGURATION ANG+% SETUP - Displays target torque plus tolerance entry screen. Advanced configuration is accessed from CONFIGURE menu selection on main menu. THEN DISABLED - Displays THEN Mode enable/disable screen. AND DISABLED - Displays AND Mode enable/disable screen.
  • Page 14 TAWM SERIES Note: UNITS button can be used to select torque units while on Torque THEN Angle screen. Note: Torque cycle is not recorded in memory unless both torque and angle reach targets. Note: Red progress lights turn on if torque exceeds 110% of wrench full scale or if angle exceeds target + plus tolerance while in manual mode.
  • Page 15: Preset Lock

    TAWM SERIES 1. From target torque screen, use UP/DOWN buttons to set target torque and UNITS button to select SLIM torque measurement units then press ENTER button. 2. Angle target screen is displayed. Use UP/DOWN buttons to set target angle then press ENTER button until Torque AND Angle mode screen is displayed.
  • Page 16: Delete Presets

    TAWM SERIES SLIM DELETE PRESETS Delete Presets function allows user to delete all presets at once. 1. From Configure menu, use UP/DOWN buttons to highlight DELETE PRESETS selection then press ENTER button. 2. Delete Presets confirmation screen is displayed. 3. Use UP/DOWN buttons to select YES or NO selection.
  • Page 17 TAWM SERIES 1. From Configure menu, use UP/DOWN buttons to highlight SET DATE/TIME selection then press 2. CAL INTERVAL screen is displayed. ENTER button. 3. Use UP/DOWN buttons to change calibration interval. 2. SET DATE screen is displayed with year highlighted.
  • Page 18: Change Password

    TAWM SERIES Note: Clock Date and Time must be set and Cal interval enabled before calibration countdown Note: Pressing POWER button at any time aborts password change sequence. will function (see Setting Date and Time and Setting Calibration Interval). Note: Calibration Countdown is number of days before wrench is locked out from use following Note: If an invalid password is entered during the confirmation step, Invalid Password Match an expired Cal interval.
  • Page 19: Troubleshooting

    TAWM SERIES IMPORTANT INFORMATION TROUBLESHOOTING Note: If any of following issues persist, return wrench to a SNA Europe/Bahco repair center. USE OF ADAPTORS, EXTENSIONS AND - Wrench must be held still during angle UNIVERSALS zeroing. Motion is indicated by alternating Anytime an adaptor, extension or universal is used dashes “- -”...
  • Page 20 TAWM SERIES 2018/11/5 (ENG) EC DECLARATION OF CONFORMITY (DEN) EF-VERENSSTEMMELSESERKLÆRING (FRA) DÉCLARATION DE CONFORMITÉ CE (NOR) ECSAMSVERKLARING (ESP) DECLARACIÓN DE CONFORMIDAD DE LA CE (FIN) EY-VAATIMUSTENMUKAISUUSVAKUUTUS (POR) DECLARAÇÃO DE CONFORMIDADE EC (RUS) Декларация о соответствии EC (ITA) DICHIARAZIONE DI CONFORMITA’ CE (TUR) CE STANDARDİZASYON BEYANI...