Mitsubishi Electric FR-A8NC Instruction Manual page 82

Hide thumbs Also See for FR-A8NC:
Table of Contents

Advertisement

 List of I/O devices whose function is changed according to the parameter settings and the
control method
Pr.544
I/O device
setting
RYD
RYE
RXD
RXE
0, 1, 12
RWw1
14, 18,
24, 28
0, 1, 12
14, 18
RWwC
24, 28
24, 28
RWwD to RWwF
*1
Pr.804 ="3 or 5" must be set.
*2
Pr.810 = "2" must be set.
*3
RYE is disabled.
*4
Torque control cannot be performed with a PM motor.
V/F control /
Advanced magnetic flux
vector control
Frequency setting command
(RAM)
Frequency setting command
(RAM, EEPROM)
Frequency setting completion
(RAM)
Frequency setting completion
(RAM, EEPROM)
Set frequency
Real sensorless vector control / vector control /
PM sensorless vector control
Speed control /
position control
Frequency setting / torque limit
command (RAM)
Frequency setting / torque limit
command (RAM, EEPROM)
Frequency setting / torque limit
completion (RAM)
Frequency setting / torque limit
completion (RAM, EEPROM)
Set frequency
*1*2
Torque limit
*2*3
Torque limit (1st quadrant)
Torque limit (2nd quadrant to 4th
*2*3
quadrant)
DETAILS OF INPUT AND OUTPUT SIGNALS
*4
Torque control
Torque command (RAM)
Torque command
(RAM, EEPROM)
Torque command completion
(RAM)
Torque command completion
(RAM, EEPROM)
*1
Torque command
Set frequency
*1
Torque command
*1
Torque command
81
7

Advertisement

Table of Contents
loading

Table of Contents