1.
Cable-end treatment
Apply the following treatment at wire end of the CC-Link dedicated cable that is inserted to a CC-Link communication
one-touch connector plug (accessory).
1. Cut the sheath
3. Cut the aluminum tape and braid.
NOTE
• Where possible, round the cable tip that is cut off with a tool such as nippers. If the cable is not rounded, it may get caught
in the middle of a plug, without fully entering into the plug.
• If required, apply an insulation treatment to the shielding wire area where it is not covered by the CC-Link communication
one-touch connector plug.
22
WIRING
2. Separate shielding wires from the drain wire. Cut the shielding wires.
4. Straighten the drain wire and twist it from the root.
(Twist seven times or more per 3 cm.)
DA (Blue)
DB (White)
DG (Yellow)
Drain wire
Drain wire
Shielding wires
DA (Blue)
DB (White)
DG (Yellow)
Drain wire (AWG20)
3 cm