accurate horizontal
® 
provided. Level 2N
® 
gently. Now 2N
Indoor View is ready for basic operation. 
Alternatively, install the device in a stand. Within installation preparations, take out the pre-
prepared cabling, UTP cable, doorbell (twin) cable and power supply. Shorten the cables to the
required length. Connect the doorbell twin cable or power supply into the connector. Crimp an
RJ-45 connector onto the UTP cable. See the figures and installation instructions below.
1.
Pull the cables through the hole in the stand bottom.
2.
First connect the green power supply/doorbell connector to the device. Then connect the
LAN connector. Install the cables carefully into the pre-prepared groove on the back side
so that they cannot get in the way and prevent free movement in the final installation
stage.
3.
Put the device on the stand making sure that it fits onto the centering pins. The aligment
of the stand bottom edge and the device bottom strip means that the device is installed
propely. Fit the device to the stand by tightening the screws through the front side. Use a
hexagon key wrench for tightening. Tighten the screws gently.
4.
Remove the protective foil from the antislip belts on the stand bottom and install the
device on a selected place. Now the device is ready for basic operation. 
®
2N
 Indoor View consumption with variable power supplies:
Supply type
PoE, IEEE 802.3af
12 V / 1 A
Warning
Do not connect any external power supply if PoE is used and vice versa.
If you use a power adapter other than the recommended one, do not exceed the 12
V rated supply voltage. Also check the supply voltage polarity. Higher voltage
values or misconnections may result in an irreplaceable device damage.

2.3 Installation Conditions

Make sure that the following 2N
There must be enough space for the device installation.
The device is designed for vertical wall mounting (perpendicular to the floor) in the height
of up to 120 cm above the floor. If necessary, operate the device in a position other than as
aforementioned for a short time only, for quick testing purposes in a servicing center, for
example.