2. Transportation and Handling

(1) Operation temperature range
Condition
Air Inlet Temperature of Outdoor Unit
Item
Cooling
(2) When transporting the outdoor unit, observe the following items. Please transport the unit to the installation location under
packed condition.
(3) When hanging the outdoor unit, please follow the description of the label attached to the outdoor unit. After
package, in order to avoid body damage, the unit needs protecting by corrugated board or cloth if moving again.
When hanging outdoor unit, please do not tie the ropes on wooden base or the inside of hanging square holes.
Example:RAM-8MQ(D)
INCORRECT
繩索
Rope
Wooden Base
Corrugated Paper Frame
Do not remove corrugated
paper and plastic bands.
Do not apply any force to
this place.(Both Sides)
Corrugated Paper Frame
Do not remove corrugated
paper and plastic bands.
Do not apply any force to
this place.(Both Sides)
-5℃ DB ~ 43℃ DB
Rope
Square
Hole
Air Inlet Temperature of Indoor Unit (Non-room Temperature)
21℃ DB/15℃ WB ~ 32℃ DB/23℃ WB
CORRECT
Rope
Square
Hole
Angle of ropes is more
than 60°.
Rope
Plywood or splint
thickness should
be more than 15mm.
Wooden Base
Apply rope through the
square holes.
Angle of ropes is more
than 60°.
Rope
Plywood or splint
thickness should
be more than 15mm.
Apply rope through the
square holes.
3
DB:Dry Bulb WB:Wet Bulb
removing the
INCORRECT