ANNUAL MAINTENANCE

Maintenance consists of the following:
Inside of the gas fi re:
Temporarily remove the door by unscrewing the screws bottom left and right,
by pulling forwards slightly at the bottom and by carefully raising the door and
taking it out.
Check the door's seal. Replace the sealing cord if necessary.
Regularly clean the glass on the inside of the appliance with glass spray or
ceramic hob cleaner.
If the glass is broken or cracked, it must be immediately replaced before
operating the fi re again.
Remove fi rst the embers and logs set from the main burner and carefully clean
these with a soft brush.
Clean and inspect (visually) the main burner, pilot light and combustion
chamber. Dust can be removed using a vacuum cleaner.
After cleaning;
Carefully replace the embers, logs set or shingles on and around the main
burner according to the installation directions in this instruction manual.
Do not place any embers, logs or shingles against the pilot light burner.
Make sure that the pilot fl ame can burn at all times freely over the main
burner. Only in this way is proper ignition of the main burner ensured.
Ignoring these directions could lead to a dangerous situation.
Check the whole gas route for leaks.
Installation instructions
It is essential that the appliance, the fl ue
and the combustion air supply
outlet are cleaned and inspected annually by a
recognised fi tter/gas specialist. The safe operation
of the appliance will thus remain guaranteed.
Caution! : Careful with glass cleaner!
Make sure that no glass cleaner liquid fl ows in the sealing of the
inside of the glass pane at the bottom of the door. Spray each time
a little glass cleaner liquid on the glass, and polish it off
immediately. Glass cleaner liquid in the sealing of the door can
cause dissolving of the black border on the inside of the glass.
It will become very spotty and can't be repaired.
Broken ceramic heat-resistant glass may not be
disposed in a glass recycling container, but must
be included in normal household waste.
English