2.1.3 Fitting into an existing opening equal to or smaller than the appliance
If the opening in the fi replace is too small for the appliance, it must be enlarged by a
recognised installer in accordance with applicable building regulations.
"Lined" installation:
Please follow the installation chronology below when positioning a fi replace:
1
Positioning of the appliance / Gas supply / Electrical connection:
Place the appliance in the open fi re place and position it by the wall. Install the
appliance using a level. Ensure the gas supply pipe has already been fed through
the designated opening at the rear (tunnel), bottom or on the side. A gas tap must
be installed in the vicinity of the appliance that must remain accessible at all times.
The Netherlands: placement of the appliance's gas tap is permitted in the meter
cupboard.
U.K./Ireland: the appliance is factory equipped with a gas tap.
If the appliance is equipped with an electrical connection (applicable if the
appliance has ambient lighting and/or AC Power adaptor), this can now be
connected to a wall socket. Ensure that during installation there is no power supply
to the wall socket. The wall socket must remain accessible at all times.
2
Dismantling the door and glass: (see pictures 2.1.2)
Dismantle the door (including the glass) by loosening left- and right under a screw
a few turns. Carefully raise the door slightly, tilt forwards and take out. Remember
to wear work gloves!
3
Removing the grate:
Remove the grate around the burner by raising it and taking it out.