Bellfires UNC-2 40 Installation Instructions & Manual For Maintenance page 17

Gas fire with open combustion system
Table of Contents

Advertisement

Bellfi res
Do not use masking tape on the appliance
when installing and plastering.
Tape can damage the fi nish of the hearth.
The brickwork or the fi re-resistant sheet construction can now be continued to ceiling
height.
If using other materials, such as stone or heat-resistant plating, you should follow the
supplier's instructions.
For further positioning instructions: See Paragraph 2.1.3.
Check that all connections are completely gas tight using soapy water or a leak tester.
As a check, allow the fi re to burn briefl y (maximum 1 minute).
Following verifi cation that there are no leaks, fi nish off building in the appliance.
After installation in a new fi replace and/or applying new cement work, the
appliance cannot be used for at least four weeks.
Installation instructions