Bellfires UNC-2 40 Installation Instructions & Manual For Maintenance page 38

Gas fire with open combustion system
Table of Contents

Advertisement

Bellfi res
Check the correct operation of the gas regulating block, thermocouple
circuit and the ignition of the main burner.
Check the gas inlet-pressure (both when the appliance is off and when it burns
at maximum) and the burner pressure.
Flue:
Inspect and clean the whole fl ue pipe and chimney outlet on the roof. Check for
cracks, loose parts, fl ue gas leakage and the overall condition of the fl ue.
If in doubt, use an inspection camera !
ƒ
Combustion air supply appliance:
Check the combustion air path from the outside air into the appliance.
Clean the combustion air supply openings in the appliance.
Dust can be removed using a vacuum cleaner.
Clean the combustion air intake openings (exterior grille).
Convection air appliance:
Check the convection air route.
Turn off the power to the appliance.
Clean the convection air intake openings, channels and outfl ow openings.
Ambient lighting (option):
...
Disconnect the power to the appliance.
Carefully clean the ambient lamps.
Replacing of the ambient lamps when broken:
First carefully separate the aluminum caps, left and right, with a nut driver No. 7
(or standard screwdriver).