Bellfi res
2.1.2 Fitting into an existing opening larger than the appliance
"Lined" installation:
Place an (insulated) aluminium or (fl exible) stainless steel pipe of Ø100 mm (Ø4") (or
Ø127 mm (Ø5") with an adapter) into the fl ue for the connection between the fl ue
spigot of the appliance and the chimney and then position the appliance into the fi re-
place. Push the aluminium or stainless steel pipe into the fl ue spigot of the appliance.
For further installation procedures, refer to paragraph 2.1.1 and 2.1.3.
"Unlined" installation (U.K. only):
Transformation from a "Lined" fl ue (top exit) connection to an "Unlined" fl ue (rear exit):
Use for this: Conversion kit "Lined"
1
Removal of the door and glass:
Remove the door (including glass) by left and right screw loosening a few turns.
Carefully lift the door slightly, tilt forward and remove. Wear gloves!
18
"Unlined" fl ue connection.