Summary of Contents for Bellfires Box Gas Panorama 73/52 MF
Page 1
I I nstallation and maintenance manual Box Gas Panorama 73/52 MF Serial number: Production date:...
Page 2
Barbas Bellfires BV. This document could contain technical inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document from time to time in the contents thereof.
Contents C C ontents About this document................5 How to work with this document....................5 Warnings and cautions used in this document................5 Related documentation........................ 5 Description....................6 Intended use..........................6 Installation options........................6 Overview of a typical installation....................6 Overview of the appliance......................7 Overview of the burner bed and the pilot light................
Page 4
5.2.4 Replace the ambient light bulb when broken..............36 Troubleshooting..................37 Technical specification................38 Box Gas Panorama 73/52 MF (MagniFire) - GB, IE, ES, IT............38 Diagram electricity and gas......................40 Dimensions Box Gas Panorama 73/52..................41 Dimensions Box Gas Panorama 73/52 with Storage module ........... 42 Dimensions Box Gas Panorama 73/52 with Support frame ............43...
• Maintenance This document refers to the Box Gas Panorama 73/52 MF as 'the appliance'. This document is an essential part of your appliance. Read it carefully before you do work on the appliance. Keep it in a safe place.
Description Description Intended use The appliance is intended for use in a completely sealed or mechanically ventilated house without extra ventilation and/or fume extraction to heat the room wherein it is installed. Do not use it for other purposes. The appliance may only be used at a location that meets the requirements for the installation of the appliance.
Description I I tem Description Concentric flue system (wall outlet variant) The concentric flue system provides combus- tion air to the appliance and extracts the flue gases from the appliance Overview of the appliance The appliance is optionally available with a support frame to attach the appliance against a wall or optional available with a storage module under the appliance.
Description I I tem Description Convection casing Collects the heated convection air. The con- vection air has a natural upward flow and is extracted by the upper front side openings of the appliance Support frame (optional) For hanging the appliance on a wall Overview of the burner bed and the pilot light Item Description...
Description 2 2 .6 Overview of the ceramic log set No. Ember grate No. Ember grate 2TV Ember grate with pilot opening No. 'Fire glass' Dark Amber No. 'Fire glass' Black Box Gas Panorama 73/52...
Page 10
Description N N o. Embers No. Charcoal No. Charcoal No. Charcoal No. Log No. Log Box Gas Panorama 73/52...
Page 11
Description N N o. Log No. Log No. Wood chip No. Wood chip Box Gas Panorama 73/52...
Description 2 2 .7 Overview of the control elements 2.7.1 Overview of the rear of the gas regulator block Item Description Inlet pressure tap Point to measure the gas supply pressure Outlet pressure tap Point to measure the front burner pressure Gas supply connection The connection for the gas supply pipe Gas connection for the front burner...
Description 2 2 .7.2 Overview of the front of the gas regulator block Description Pilot gas adjustment screw Sets the pilot light gas pressure. The adjust- ment screw is factory set and sealed. Adjustment screw maximum burner pressure Sets the maximum gas pressure for the burn- er.
Description 2 2 .7.3 Overview of the connections on the gas regulator block Item Description Pilot light pipe Supplies gas to the pilot light burner Thermocouple Detects if the pilot light is on Connector (nut-olive) Ø 4mm Connects the pilot light gas pipe to the gas regulator block Thermocouple interrupter Interrupts the signal of the thermocouple, and...
Connection for a wifi-box (SI) Optionally, a wifi-box can be connected to the receiver to control the appliance with a smart- phone or tablet with the Bellfires app Connection for the fan/light module (MOD- To control the light function ULE)
Description 2 2 .7.5 Overview of the fan/light module Item Description Connection for the ambient lights Powers the ambient light bulbs Connection for a convection fan Not applicable for this appliance connection for the power supply Connection for the 230 VAC power cable with an earthed plug.
Safety Safety Safety devices on the appliance Name Description Thermo-electric pilot light shut off Prevents unforseen discharge of gas from the main burner. Overpressure door (= glass front) and If an overpressure occurs in the appliance, the glass overpressure hatch front door and the hatch opens for a short duration.
Safety 3 3 .3 Safety distances to flammable and nonflammable materials Note: Make sure that flammable materials near the appliance can never reach a temperature above 85 degrees centigrade. Box Gas Panorama Box Gas Panorama Label Minimum distance Remark Minimum distance Remark to flammable mate- to nonflammable...
Page 19
Safety B B ox Gas Panorama Box Gas Panorama Label Minimum distance Remark Minimum distance Remark to flammable mate- to nonflammable rials in cm materials in cm Box Gas Panorama with Storage Module Box Gas Panorama with Storage Module Label Minimum distance Remark Minimum distance...
Safety B B ox Gas Panorama with Support Frame Box Gas Panorama with Support Frame Label Minimum distance Remark Minimum distance Remark to flammable mate- to nonflammable rials in cm materials in cm Do not install Support frame can against a flamma- be attached directly Not allowed ble wall.
Installation Installation Installation prerequisites Make sure that the location agrees with the requirements. Refer to the preparation manual. Make sure that the details of the rating plate of the appliance agree with the gas type and gas pressure of the gas supply. Installation procedure Note: The appliance is factory set to the correct nominal heat input.
• Use the optional support frame to attach the appliance to a wall. • Bellfires does not supply the screws for the attachment of the support frame on the wall. Use appropriate screws applicable for the wall. • The support frame must be attached to the wall by minimum 4 appropriate screws.
Installation Mark the locations on the wall for the 4 corner screws by which the support frame is attached to the wall. Make sure the support frame is horizontal when marking the locations. Use a spirit lever. Drill the 4 holes. Attach the support frame to the wall with appropriate screws.
Installation 4 4 .2.6 Do a check on the gas connections • Make sure that the gas connections do not leak. Use soapy water or a leak tester. 4.2.7 Make the electrical connection Caution: • Use a wall socket with earth connection. •...
Installation Safety conditions W W arning: Always remove the baffle plate if there is no need to mount a restriction plate!!! No restriction plate → No baffle plate !!!!! Failure to remove the baffle plate, if there is no need to mount a restriction plate, can lead to dangerous situations! Procedure Remove the baffle plate, by...
Installation 4 4 .3.2 Put the ceramic log set on the burner bed Safety conditions Warning: • Make sure that none of the openings of the ember grates (A) are blocked. Blockage of the openings of the ember grates can lead to a dangerous situation.
Page 27
Installation P P reparation Make sure that all items of the log set are there. See Put the ceramic ember grates on the lower and upper main burner, as shown below. Refer to for the numbers of the items. Box Gas Panorama 73/52...
Page 28
Installation Spread the fire glass -dark amber- evenly on the metal grate in front of the burner bed. Spread the fire glass -black- evenly on the metal grate on the left (L) and right (R) of the burner bed. N N ote: Set the light intensity of the ambient lighting to maximum on the remote control.
Page 29
Installation Spread the embers evenly behind and beside the burner bed. C C aution: Do not apply embers on the openings of the ember grates. Embers in the openings of the ember grates can cause a blockage of the openings. Put the charcoal pieces and chips of wood at the designated places around the burner bed.
Page 30
Installation Put the logs on the burner bed. Refer to for the numbers of the items. 5.2.2 Install the glass. Refer to 3 3 0 Box Gas Panorama 73/52...
Installation 4 4 .3.3 Do a final check on the appliance Safety conditions Caution: A final check on the appliance can be done directly after the installation. Procedure Start the appliance and do a check on the ignition of the pilot light and main burner. The ignition must be quiet and must produce a calm flame.
• Do all procedures in this section every year. Caution: • Use only original parts. Individual parts for replacement or accessories are available from your BELLFIRES-dealer. • Introduced modifications to the appliance are not permitted. 5.1.1 Clean the appliance Safety conditions Caution: •...
Maintenance Make sure that the main burner operates correctly. The fire must not show any anomalies. Do a check of the gas supply pressure and the burner pressure. Use the inlet pressure tap and outlet pressure tap on the gas regulator block to measure the supply pressure and the burner pressure.
Maintenance Loosen the screws left and right of the top side strips. Do not remove the screws and strips. Remove the glass panes on the sides with the same procedure as the front glass. 5 5 .2.2 Install the glass panes Caution: Use protective gloves.
Page 35
Maintenance Tighten the screws left and right of the top side strips. Install the front glass pane, by lifting the glass a little in a slanted manner and place it in the strips (top and bottom) . Lock the fastening levers on the top left and right of the glass panes. Install the front panel and side panels.
Maintenance C C aution: • Make sure whether the front glass pane is placed exactly in the middle. • Make sure that there are no gaps between the glass panes. Otherwise, there is risk of flue gas leakage. 5.2.3 Clean the glass Clean the glass with a soft cloth, a sponge or paper.
Troubleshooting Troubleshooting Problem possible cause solution The main fire stops to burn The concentric flue system is Install the concentric flue sys- not installed according to the tem correctly. Refer to the specified instructions. preparation manual. An incorrect flue gas restriction Install the correct gas restric- 4.2.9 plate is fitted.
Technical specification Technical specification Box Gas Panorama 73/52 MF (MagniFire) - GB, IE, ES, IT Natural gas Butane/ Propane Name Bellfires Bellfires Model Box Gas Panorama 73/52 MF Box Gas Panorama 73/52 MF Country GB, IE, ES, IT GB, IE, ES, IT...
Page 39
Technical specification N N atural gas Butane/ Propane Pilot light burner SIT 0.145.019 SIT 0.145.019 Pilot light burner injector no 36 (SIT 0.977.091) no 23 (SIT 0.977.150) Gas connection 3/8” G / Ø12 mm 3/8” G / Ø12 mm Concentric flue system connec- Ø100 mm - Ø150 mm Ø100 mm - Ø150 mm tion...
Technical specification 7 7 .2 Diagram electricity and gas Item Main burners Gas regulator block Gas valve of the rear burner Receiver Fan/Light module Ambient lighting Gas pipe rear burner Gas pipe front burner Gas supply connection Pilot light burner Pilot light pipe Piezo cable Thermocouple...
Technical specification 7 7 .6 Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection Ø100 - Ø150 Roof-mounted outlet Box Gas Panorama 73/52...
Complaints will only be accepted if they are reported to the Bellfires dealer, together with the serial number of the Bellfires appliance which is stated on the front of the user manual. In addition, the original receipt (invoice, receipt, cash receipt) showing the date of purchase must also be submitted.
Page 46
Article 5: Warranty period This warranty will only be granted during the warranty period. The body of the Bellfires appliance is guaranteed for a period of 10 years against construction and/or material faults, starting from the moment of purchase. For other parts of the Bellfires appliance, a similar warranty applies from the moment of purchase for a period of two years.
Need help?
Do you have a question about the Box Gas Panorama 73/52 MF and is the answer not in the manual?